New Zealand Geothermal Workshop · Session 5.1: Production

Testing of cyclone separators and steam pipelines for separation and scrubbing performance

T. Misa, E. Mroczek

Abstract

Testing for separation and scrubbing performance was undertaken on Intermediate Pressure (IP) and Low Pressure (LP) steam systems of a geothermal steamfield and power station. Testing was completed at a number of process conditions to determine what operating conditions caused changes in separation and scrubbing performance.
A suite of steam and separated water flow measurements were used in conjunction with changes in natural sodium and injected fluorescein carryover to observe the effect on plant performance. Results showed an unexpected significant holdup time of the added tracer, separator performance below design and the effects of flow regimes and geometries on system performance. Difficulties and benefits of completing this type of testing on operational industrial plant are discussed.

Details

Conference
New Zealand Geothermal Workshop
Year
2017
Session
Session 5.1: Production
Paper number
71
Language
English
Copyright
University of Auckland
Keywords
steam separation two phase flow pipeline scrubbing steam sampling tracer testing steam cleanliness steam purity steam quality
Record ID
28092

Suggested citation

T. Misa, E. Mroczek (2017). Testing of cyclone separators and steam pipelines for separation and scrubbing performance. Proceedings, New Zealand Geothermal Workshop 2017, Paper 71.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Misa ›