World Geothermal Congress · 29. Geothermal Heat Pumps

A Novel Coaxial Borehole Heat Exchanger: Description and First Distributed Thermal Response Test Measurements

José Acuña, Björn Palm

Abstract

The thermal performance of a Borehole Heat Exchanger plays a significant role when defining the quality of heat exchange with the ground in Ground Source Heat Pumps. Different designs have been discussed and increased interest on innovation within this field has taken place during the last years. This paper presents the first measurement results from a 189 meters deep novel coaxial Borehole Heat Exchanger, consisting of an inner central pipe and an annular channel in direct contact with the surrounding bedrock. The measurements were taken during a distributed thermal response test using fiber optic cables installed in the energy well. Fluid temperature every ten meters along the borehole depth are presented and compared with similar measurements from a common U-pipe heat exchanger. A unique measurement of the borehole wall temperature in the coaxial collector illustrates how effective the heat transfer performance is through the annular channel.

Details

Conference
World Geothermal Congress
Year
2010
Session
29. Geothermal Heat Pumps (44 papers)
Paper number
2953
Language
English
Copyright
International Geothermal Association
Keywords
Borehole Heat Exchanger Ground Source Heat Pump Distributed Thermal Response Test Coaxial U-pipe borehole wall temperature measurement
Record ID
6646

Suggested citation

José Acuña, Björn Palm (2010). A Novel Coaxial Borehole Heat Exchanger: Description and First Distributed Thermal Response Test Measurements. Proceedings, World Geothermal Congress 2010, Paper 2953.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Acuña ›