World Geothermal Congress · SECTION 7 - Field Management and Monitoring

Interference Test Analysis Method in the Presence of a Linear Boundary Field

Ryuichi Itoi and Michihiro Fukuda

Download PDF

Abstract

A method has been developed for analyzing interference test data in the presence of a hydrologic boundary. Kalman filtering algorithm has been applied as a parameter estimating method to the line source solution that expresses pressure response caused by fluid production and/or injection at active wells. This solution is modified to express the effects of the presence of the boundary on pressure response. The analysis method comprises two steps. First, an infinite reservoir model will be used for analyses, and performances of the estimated values of parameters, transmissivity and storativity, with time would provide information on the presence of the boundary and its impermeable boundary or a constant pressure boundary. On the basis of this result, an appropriate model will be assigned to reanalyze the data. Synthetic data was analyzed to validate the use of the method, and the estimated values of the parameters are to be satisfactory.

Details

Conference
World Geothermal Congress
Year
1995
Session
SECTION 7 - Field Management and Monitoring (36 papers)
Paper number
3-itoi
Language
English
Copyright
International Geothermal Association
Keywords
interference test analysis method linear boundary transmisivity storativity
Record ID
4766

Suggested citation

Ryuichi Itoi and Michihiro Fukuda (1995). Interference Test Analysis Method in the Presence of a Linear Boundary Field. Proceedings, World Geothermal Congress 1995, Paper 3-itoi.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Itoi ›