World Geothermal Congress · SECTION 7 - Field Management and Monitoring

Cooling Effect and Fluid Flow Behavior Due to Reinjected Hot Water in the Hatchobaru Geothermal Field, Japan

Hiroyuki Tokita, Tetsuya Yahara and lsao Kitakoga

Download PDF

Abstract

In the Hatchobaru geothermal field, the power output had declined due to a cooling effect from 110 to 90 within the first two years after commencement of commercial operation of the second power unit Unit). In order to clarify this cooling mechanism, tracer tests and numerical simulations were conducted. The simulation results show that 21% of reinjected hot water returned to the production area, and the temperature of production area dropped subsequently by within the first two years. Furthermore, results of case studies suggest that a distance of more than 500 m between production area and reinjection area are necessary to mitigate the cooling effect. Therefore, the locations of most reinjection wells were changed so that they were at least m away from the production area. As a result, the declining trend of power output was actually reduced.

Details

Conference
World Geothermal Congress
Year
1995
Session
SECTION 7 - Field Management and Monitoring (36 papers)
Paper number
3-tokita
Language
English
Geographic area
Otake-Hatchobaru, Japan
Copyright
International Geothermal Association
Keywords
cooling effect Hatchobaru injection pressure simulation tracer test
Record ID
4841

Suggested citation

Hiroyuki Tokita, Tetsuya Yahara and lsao Kitakoga (1995). Cooling Effect and Fluid Flow Behavior Due to Reinjected Hot Water in the Hatchobaru Geothermal Field, Japan. Proceedings, World Geothermal Congress 1995, Paper 3-tokita.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Tokita ›