World Geothermal Congress · Corrosion and Scaling

Simultaneous Silica Treatment Qualification Using On-Site Side Stream Test Rig

Dana Marie SUNGA, Richard DE GUZMAN, Miguel RAMOS, Michelle BIBON, Antonio LORENZO, Fidel SEE, Edwin ALCOBER

Abstract

An on-site side stream test program has been developed to thoroughly assess the required mitigation for silica scaling of a proposed brine optimization project in Bacon Manito (BacMan), Sorsogon, Philippines. The test rig simulated the temperature drops, residence time, and flow regime of the brine-optimization-plant-to-reinjection system. A base-case test line and treatment lines with dosing provision were simultaneously operated for ~30 days, alongside a field laboratory for immediate silica analysis. Out of four different chemical treatments, the most effective silica inhibition method was evaluated based on silica retention performance, and volume of actual scale deposits formed. Brine pH modification proves to be the most efficient silica scaling mitigation method for the project area, resulting to manageable scaling rates.

Details

Conference
World Geothermal Congress
Year
2020
Session
Corrosion and Scaling (77 papers)
Paper number
27021
Language
English
Copyright
International Geothermal Association
Keywords
silica scaling acid pH modification acid dosing side stream test BacMan Philippines
Record ID
34376

Suggested citation

Dana Marie SUNGA, Richard DE GUZMAN, Miguel RAMOS, Michelle BIBON, Antonio LORENZO, Fidel SEE, Edwin ALCOBER (2020). Simultaneous Silica Treatment Qualification Using On-Site Side Stream Test Rig. Proceedings, World Geothermal Congress 2020, Paper 27021.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Sunga ›