Stanford Geothermal Workshop · Tracers

Radon Anomaly at the Antung Hot Spring before the Taiwan M 6.8 Chengkung Earthquake

T. Kuo, K. Fan, W. Chen, H. Kuochen, Y. Han, C. Wang, T. Chang,Y. Lee

Download PDF (153KB) Hosted on pangea.stanford.edu

Abstract

The 2003 Chengkung earthquake of magnitude (M) 6.8 on December 10, 2003 was the strongest earthquake near the Chengkung area in eastern Taiwan since 1951. The radon-monitoring station at the Antung hot spring as located 20 km from the epicenter. Approximately 65 days prior to the 2003 Chengkung earthquake, precursory changes in the groundwaterís radon concentration were observed. The radon anomaly was a decrease from a background level of 780 pCi/L to a minimum of 330 pCi/L. Observations at the Antung hot spring suggest that the groundwater radon, when observed under suitable geological conditions, can be a sensitive tracer for strain changes in the crust preceding an earthquake. The Antung hot spring is situated in a tuffaceous-sandstone fractured block inside mudstone. Under such geological conditions, the dilation of rock masses was produced at a rate faster than the recharge rate of pore water and gas saturation developed in rock cracks preceding the earthquake. Meanwhile, the radon in groundwater volatilized and partitioned into the gas phase. Our understanding of geology and radon phase-behavior would help select radon-monitoring sites in the future.

Details

Conference
Stanford Geothermal Workshop
Year
2006
Session
Tracers
Paper number
Kuo
Language
English
Geographic area
Antung Hot Spring, Taiwan
Copyright
Stanford Geothermal Program
Keywords
radon anomaly earthquake precursor tracer Antung hot spring
Record ID
3084

Suggested citation

T. Kuo, K. Fan, W. Chen, H. Kuochen, Y. Han, C. Wang, T. Chang,Y. Lee (2006). Radon Anomaly at the Antung Hot Spring before the Taiwan M 6.8 Chengkung Earthquake. Proceedings, Stanford Geothermal Workshop 2006, Paper Kuo.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Kuo ›