Tracer flow testing trials have been conducted in Indonesia to assess the accuracy of the isopropanol (IPA) tracer flow testing procedure. Flow measurements from production wells were compared with physical measurements and alternative tracer flow measurements (SF6). The testing was conducted with production well flowrates in the range 25-110 kg/s and enthalpies in the range 1350 - 2800 kJ/kg. Results are presented for tests conducted between 2001-2003. The mean difference in steam flows for IPA and SF6 tracer testing was about 6%, with no systematic bias. For dry steam wells, the difference between IPA flows and orifice plate measurements was a mean 1.2% for 12 tests. The results confirm that IPA tracer flow testing is a viable method over a wide range of operating conditions.

Details

Conference
Stanford Geothermal Workshop
Year
2006
Session
Tracers
Paper number
Lovelock
Language
English
Geographic area
Wayang Windu, Indonesia; Java
Copyright
Stanford Geothermal Program
Record ID
3041

Suggested citation

Brian Lovelock (2006). Flow Testing in Indonesia using Alcohol Tracers. Proceedings, Stanford Geothermal Workshop 2006, Paper Lovelock.