Geothermal Resources Council Transactions · Power plant design and operation; Two phase flow; Flash stea
Broadlands Optimisation
Download unavailable for this file.
Abstract
A lumped parameter model of Broadlands geothermal field was used to study possible power station configurations. For two stage flash, a broad optimum was found in the inlet pressure on the turbine, from 6 to 10 bar with a value at the low end of range, 6.2 bar being recommended. A three stage flash was also considered, and the best choice was the use of temporary HP topping, sets. These HP sets would be sustained for one third of the stations lifetime.
Details
Suggested citation
Grant, Malcolm A. (1979). Broadlands Optimisation. Proceedings, Geothermal Resources Council Transactions 1979.
Proceedings-level reference. Individual papers do not carry DOIs.