Geothermal Resources Council Transactions · Power plant design and operation; Two phase flow; Flash stea

Broadlands Optimisation

Grant, Malcolm A.

Download unavailable for this file.

Abstract

A lumped parameter model of Broadlands geothermal field was used to study possible power station configurations. For two stage flash, a broad optimum was found in the inlet pressure on the turbine, from 6 to 10 bar with a value at the low end of range, 6.2 bar being recommended. A three stage flash was also considered, and the best choice was the use of temporary HP topping, sets. These HP sets would be sustained for one third of the stations lifetime.

Details

Conference
Geothermal Resources Council Transactions
Year
1979
Session
Power plant design and operation; Two phase flow; Flash stea
Language
English
Geographic area
Broadlands, New Zealand; Ohaaki, New Zealand; Taupo Volcanic Zone
Copyright
Geothermal Resources Council
Keywords
Reservoir Engineering Power Plant New Zealand North Island Broad Lands Well Tests Plant Design Simulation Field Capacity Power Cycle Flash Steam Ohaaki Mass Flow Production History Reinjection DSIR
Record ID
14511

Suggested citation

Grant, Malcolm A. (1979). Broadlands Optimisation. Proceedings, Geothermal Resources Council Transactions 1979.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Grant, Malcolm A. ›