Geothermal Resources Council Transactions · Pipelines; Two phase flow; Fluid dynamics

Two Phase Pressure Drop Measurements on a Geothermal Pipeline

Freeston, Derek H.; Lee, Keng C.

Download unavailable for this file.

Abstract

This paper details an investigation of two phase, water/steam, pressure drop on a 10 cm diameter test loop sited on the Wairakei (NZ) steam field. Measurements of straight pipe and duct component losses are presented using a liquid velocity derived from a void fraction correlation. A horizontal flow straight pipe correlation is presented based on data from a 20 cm diameter pipeline and component pressure losses are demonstrated to be of such a magnitude as to be significant in a two phase pipeline reticulation system.

Details

Conference
Geothermal Resources Council Transactions
Year
1979
Session
Pipelines; Two phase flow; Fluid dynamics
Language
English
Geographic area
Wairakei, New Zealand; Taupo Volcanic Zone
Copyright
Geothermal Resources Council
Keywords
Two Phase Flow Economics Test Loop Pressure Drop New Zealand Wairakei Pipe Line Pressure Loss Measurements Correlation 20 CM Separate Quality Pipe Line Design Instabilities Mist Slug Flow Water Hammer Vibration Void Fraction Universit
Record ID
14502

Suggested citation

Freeston, Derek H.; Lee, Keng C. (1979). Two Phase Pressure Drop Measurements on a Geothermal Pipeline. Proceedings, Geothermal Resources Council Transactions 1979.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Freeston, Derek H.; Lee, Keng ›