K. Lichti, R. Julian, C. Davies, B. Fletcher, K. Osato, M. Sato, K. Kasai, N. Yanagisawa, K. Sakura
·
New Zealand Geothermal Workshop
·
2020
·Session 5.2 Above Ground Technology 3
Small bore corrosion test loops in side streams have been commonly used for many years in the oil and gas industry for cooling water corrosion monitoring. This work describes a high temperature flowing brine test loop for on-line Electrical Resistance, Linear …
View paper: Cfd Modelling of Corrosion Test Loops for Geothermal Fluid Applications
PDF: Cfd Modelling of Corrosion Test Loops for Geothermal Fluid Applications (681KB)
-
N. Yanagisawa,Y. Masuda, K. Osato, M. Sato, K. Kasai, K. Sakura, T. Fukui, M. Akahori and K. Lichti
·
New Zealand Geothermal Workshop
·
2017
·Session 3.2 Scaling
… Okuaizu geothermal power plant using small loop test system in February of 2017. We carried out several corrosion tests, 1 day, 4 days and 15 days testing under about pH 3.8 and 165 degreeC condition which gave us low corrosion rates. And we …
View paper: THE MATERIAL CORROSION TEST USING LOOP SYSTEM UNDER ACIDIC CONDITION AT GEOTHERMAL FIELD IN JAPAN
PDF: THE MATERIAL CORROSION TEST USING LOOP SYSTEM UNDER ACIDIC CONDITION AT GEOTHERMAL FIELD IN JAPAN (502KB)
-
Meissam L. Bahlali, Carl Jacquemyn, Matthew Jackson, Adrian Butler, Joseph Kelly, Fleur Loveridge, Dave
·
World Geothermal Congress
·
2026
·Reservoir Testing, Thermal Response and Flow Diagnostics
… We present numerical modelling of a Thermal Response Test (TRT) and an Open Loop Thermal Tracer Test (OL-TTT) conducted in the same Chalk borehole in Berkshire, UK. Extensive monitoring included distributed temperature sensors, electrical resistivity …
View paper: Modelling Thermal Response and Tracer Tests in a Complex Fractured Aquifer System
PDF: Modelling Thermal Response and Tracer Tests in a Complex Fractured Aquifer System
-
Vetter, O. J.; Campbell, D. A.; Walker, M. J.
·
Geothermal Resources Council Transactions
·
1978
·Brine chemistry; Scaling; Flash steam power generation; Sili
This paper summarizes some of the experiments and tests performed thus far in the northern apart of the East Mesa Geothermal Field operated by REPUBLIC GEOTHERMAL, INC. (RGI). The investigation described concern only the fluid characteristics pertinent to …
View paper: Geothermal Fluid Investigations at Republic's East Mesa Test Site
Download unavailable
-
David Wilson and Kelly Harris
·
Western Pacific Regional Branch
·
2011
… inhibitor and uses simple jar and dynamic scale loop tests to evaluate the inhibitor compared to a commercial „green‟ inhibitor for carbonate scales. Hydrothermal studies performed under differing pH regimens demonstrate stability to 200°C …
View paper: Development of a 'Green' Hydrothermally Stable Scale Inhibitor for Geothermal Wells and Pipelines
PDF: Development of a 'Green' Hydrothermally Stable Scale Inhibitor for Geothermal Wells and Pipelines (270 KB)
-
Freeston, Derek H.; Lee, Keng C.
·
Geothermal Resources Council Transactions
·
1979
·Pipelines; Two phase flow; Fluid dynamics
… two phase, water/steam, pressure drop on a 10 cm diameter test loop sited on the Wairakei (NZ) steam field. Measurements of straight pipe and duct component losses are presented using a liquid velocity derived from a void fraction correlation. A horizontal …
View paper: Two Phase Pressure Drop Measurements on a Geothermal Pipeline
Download unavailable
-
Vetter, O. J.; Campbell, D. A.
·
Geothermal Resources Council Transactions
·
1979
·Geochemical surveys; Carbonates; Scaling
… 2060) at the wellhead. Fluid flow was directed through a test loop which simulated a flash cycle power plant. it was found that all carbonate scales can be avoided at a cost of less that 0.3 mills/KWhr in a planned 64 MW power plant. The critical range of …
View paper: Carbonate Scale Inhibition in Republic's East Mesa Geothermal Operations
Download unavailable
-
Lombard, Gilbert L.
·
Geothermal Resources Council Transactions
·
1977
·Power plant design and operation; Economics; Liquid dominate
… of this paper. In 1973 SDG&E participated in well flow tests at Heber and in 1974 conducted a series of heat exchanger tests with the Heber fluid. This fluid contains 14,000 ppm and at a temperature of 360°F. These tests at Heber indicated no great …
View paper: Heber Geothermal Demonstration Plant
Download unavailable
-
Keith LICHTI, Rosalind JULIAN, Kevin BROWN, Gener VILLAFUERTE, Richard DAMBE
·
World Geothermal Congress
·
2020
·Corrosion and Scaling
… temperature in a small bore heat exchanger was used to test carbon steel corrosion rates under simulated heat exchange and reinjection conditions. The results obtained showed silica could be kept in solution under the selected conditions. However, onset …
View paper: Scaling and Corrosion Control in a High Chloride Geothermal Brine
PDF: Scaling and Corrosion Control in a High Chloride Geothermal Brine (882 KB)
-
Geyer, John D.
·
Geothermal Resources Council Transactions
·
2009
·Geothermal heat pumps; Geothermal overviews; Space heating/c
… simplicity, adequate flushing and purging access for water loops, low-tech controls and thermally “tight” building construction. Advanced design practices include integration of simultaneous heating and cooling loads, use of Heat Recovery Ventilators to …
View paper: Geothermal Heating and Cooling System Design Process
Download unavailable
-
Rand, Peter B.
·
Geothermal Resources Council Transactions
·
1979
·Drilling; Drilling fluids
… paper presents the procedures developed to generate and test aqueous foams and the effects at 260°C temperature cycle on aqueous surfactant solutions. More than fifty selected surfactants were evaluated, with representatives from the amphoteric, anionic, …
View paper: Aqueous Foams for Geothermal Drilling Fluids I: Surfactant Screening
Download unavailable
-
Vandevier, Joe; Gould, Ben
·
Geothermal Resources Council Transactions
·
2009
·Well pumps
The need for artificial lift to improve the economics of geothermal fluids production for power generation and direct use applications has been recognized for many years. Electrical submersible pumping (ESP) systems have been used successfully in geothermal …
View paper: Application of Electrical Submersible Pumping Systems in High Temperature Geothermal Environments
Download unavailable