New Zealand Geothermal Workshop · Geothermal Engineering - Production and Management

Optimisation Of A Fin Fan Condenser In A Geothermal ORC Plant

Proctor, Matthew ., Yu, Wei ., Young, Brent . and Kirkpatrick, Robert

Abstract

A case study is performed on the fin fan condenser of one organic Rankine cycle (ORC) unit at the Ngawha Geothermal Power Station, Northland, to optimise the number of fans to maximise the economics of the ORC while maintaining safe operation. A practical method is shown where first, key parameters of the fin fan condenser are identified followed by the use of these parameters in a plant model to predict the effect of varying the number of fans and condenser area on the power output of the entire ORC. The number of fans is determined using a heuristic that accounts for the trade-off between capital cost and revenue as well as safety issues that arise as a result of increasing the condenser duty. Finally, the economics of investing in additional condenser equipment is evaluated by calculating the payback period. This involves calculating the increased revenue compared to existing operation, taking into account real air temperature data for the plant, and estimating the capital cost of the additional equipment.

Details

Conference
New Zealand Geothermal Workshop
Year
2014
Session
Geothermal Engineering - Production and Management
Paper number
37
Language
English
Copyright
University of Auckland
Keywords
condenser air cooled optimisation organic Rankine cycle
Record ID
20320

Suggested citation

Proctor, Matthew ., Yu, Wei ., Young, Brent . and Kirkpatrick, Robert (2014). Optimisation Of A Fin Fan Condenser In A Geothermal ORC Plant. Proceedings, New Zealand Geothermal Workshop 2014, Paper 37.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Proctor ›