Skip to content
International Geothermal Association Conference Paper Database Live

Searches title, authors, abstract, keywords and session. Use "quotes" for an exact phrase.

Advanced search

All filled fields must match. Conference and year are added to the filters on the left.

Filters

Show filters
Conference
Year
–

1–25 of 130 papers

  1. Real Time Monitoring of Airborne Hydrogen Sulfide Using Pulsed Fluorescence SO2-H2S-CS Analyzers

    Sverrir Oskar ELEFSEN, Asgerdur K. SIGURDARDOTTIR · World Geothermal Congress · 2020 ·Environmental Aspects

    … from real time monitoring of Airborne Hydrogen Sulfide (H2S) in NE-Iceland, i.e. the lake Mývatn area, town of Húsavík and the area of Kelduhverfi. In general, the H2S concentration is low and below regulatory limits in all the areas. Located close to …

    View paper: Real Time Monitoring of Airborne Hydrogen Sulfide Using Pulsed Fluorescence SO2-H2S-CS Analyzers PDF: Real Time Monitoring of Airborne Hydrogen Sulfide Using Pulsed Fluorescence SO2-H2S-CS Analyzers (1131 KB)

  2. GECO: Geological Properties, Permeability and Porosity of the Nesjavellir High Temperature Area in Relation to the Re-injection of Geothermal CO2 and H2S Gases

    Sveinborg H. GUNNARSDOTTIR, Helga M. HELGADOTTIR, Sandra O. SNÆBJÖRNSDOTTIR · World Geothermal Congress · 2020 ·Geology

    … is to prepare for re-injection of geothermal CO2 and H2S from the Nesjavellir Power Plant in SW-Iceland. The gases are dissolved in water and injected into the subsurface for permanent storage via mineralization. This requires a thorough understanding …

    View paper: GECO: Geological Properties, Permeability and Porosity of the Nesjavellir High Temperature Area in Relation to the Re-injection of Geothermal CO2 and H2S Gases PDF: GECO: Geological Properties, Permeability and Porosity of the Nesjavellir High Temperature Area in Relation to the Re-injection of Geothermal CO2 and H2S Gases (1352 KB)

  3. Risk Mitigation of H2S Exposure at ON Power

    Dagur HELGASON, Iða Brá VILHJÁLMSDÓTTIR, Sæunn Kolbrún ÞÓRÓLFSDÓTTIR · World Geothermal Congress · 2020 ·Environmental Aspects

    The biggest threat to ON Power power plant’s employees is H2S, a colorless, flammable and toxic gas which can cause death in high concentrations. H2S is one of the NCGs (non-condensable gases) contained in the geothermal fluid. Each employee has his/her …

    View paper: Risk Mitigation of H2S Exposure at ON Power PDF: Risk Mitigation of H2S Exposure at ON Power (1164 KB)

  4. Evaluation of the Interactions Between Hydrogen and Steel in Geothermal Conditions with H2S

    KITTEL Jean, ROPITAL Francois, GROSJEAN François, JOSHI Gaurav · World Geothermal Congress · 2020 ·Corrosion and Scaling

    … Corrosivity is enhanced when acid gases such as CO2 and H2S are present. In addition to localized or uniform corrosion, H2S also promotes hydrogen entry into the steels, resulting in a reduction of mechanical strength. Depending on the metallurgical …

    View paper: Evaluation of the Interactions Between Hydrogen and Steel in Geothermal Conditions with H2S PDF: Evaluation of the Interactions Between Hydrogen and Steel in Geothermal Conditions with H2S (900 KB)

  5. H2S Corrosion of Carbon Steel in Geothermal Fluids

    S. Ghaziof, R. Dudley, R. Julian, M. Ko and K. Lichti · New Zealand Geothermal Workshop · 2017 ·Session 3.2 Scaling

    Corrosion of carbon and low alloy steels in H2S containing geothermal two phase fluids, separated steam and superheated steam has long been known to be controlled by the formation of adherent and continuous iron sulphide and iron oxide corrosion products that …

    View paper: H2S Corrosion of Carbon Steel in Geothermal Fluids PDF: H2S Corrosion of Carbon Steel in Geothermal Fluids (698KB)

  6. Design of an H2S Absorption Column at the Hellisheiði Powerplant

    Ari INGIMUNDARSON, Magnús Þór ARNARSON, Húni SIGHVATSSON, Teitur GUNNARSSON · World Geothermal Congress · 2015 ·Power Generation

    … in Iceland impose conditions on disposal and abatement of H2S release from geothermal power plants. At the Hellisheiði power plant several methods of H2S disposal have been under investigations. After an initial screening the most suitable methods were …

    View paper: Design of an H2S Absorption Column at the Hellisheiði Powerplant PDF: Design of an H2S Absorption Column at the Hellisheiði Powerplant (607 KB)

  7. Review of H2S Abatement Methods in Geothermal Plants

    Esteban RODRIGUEZ, William Scott HARVEY, Einar Jón ÁSBJÖRNSSON · World Geothermal Congress · 2015 ·Corrosion and Scaling

    … dissolved non-condensable gases (NCG) such as CO2 and H2S within geothermal fluids have led to increased interest in developing methods for decreasing these emissions through abatement systems, or potentially using these gases to generate value for use …

    View paper: Review of H2S Abatement Methods in Geothermal Plants PDF: Review of H2S Abatement Methods in Geothermal Plants (455 KB)

  8. ELECTRO-FENTON AND ELECTROCOAGULATION FOR SMALL SCALE REMOVAL OF H2S FROM GEOTHERMAL GAS STREAMS

    E. Mroczek and D. Graham · New Zealand Geothermal Workshop · 2015 ·Session 3A

    … electro-fenton and electrocoagulation processes to remove H2S from condensed steam at Wairakei. The cooled condensate and accompanying gas (~0.4wt% gas in total of which 97wt% is CO2 and 1.5wt% H2S) is passed through the electrochemical cell at 450 ml/min. …

    View paper: ELECTRO-FENTON AND ELECTROCOAGULATION FOR SMALL SCALE REMOVAL OF H2S FROM GEOTHERMAL GAS STREAMS PDF: ELECTRO-FENTON AND ELECTROCOAGULATION FOR SMALL SCALE REMOVAL OF H2S FROM GEOTHERMAL GAS STREAMS (143.52 KB)

  9. Review of H2S Abatement Methods in Geothermal Plants

    Esteban RODRIGUEZ, William Scott HARVEY, Einar Jón ÁSBJÖRNSSON · Stanford Geothermal Workshop · 2014 ·General

    … dissolved non-condensable gases (NCG) such as CO2 and H2S within geothermal fluids have led to increased interest in developing methods for decreasing these emissions through abatement systems, or potentially using these gases to generate value for use …

    View paper: Review of H2S Abatement Methods in Geothermal Plants PDF: Review of H2S Abatement Methods in Geothermal Plants (372 KB)

  10. Improvements in Residence Time and Air Oxidation For H2S Abatement in The Geysers' Geothermal Power Plants With Direct-Contact Condensers and Crossflow Cooling Towers

    Hillard, Catherine; Benn, Brian · Geothermal Resources Council Transactions · 2014 ·Power plant design and operation; Effluent abatement; Air qu

    H2S abatement efficiency in geothermal crossflow cooling towers can be improved by increasing the reaction time and dissolved oxygen concentration in the circulating water (Ballantine, 1993). Additional efficiency is accomplished at Geysers? units with …

    View paper: Improvements in Residence Time and Air Oxidation For H2S Abatement in The Geysers' Geothermal Power Plants With Direct-Contact Condensers and Crossflow Cooling Towers Download unavailable

  11. Assessment of Geothermal Power Plants Impact on Air Quality – Effect of H2S Abatement with AMIS in the Larderello-Travale-Radicondoli Geothermal Area (Tuscany).

    Pertot, Sabatelli, Messia, D’aleo: · European Geothermal Conference · 2013 ·4 Environment (ENV)

    … impact associated with emissions of hydrogen sulfide (H2S) and mercury (Hg) in the Larderello-Travale-Radicondoli Geothermal Area (Tuscany). The AMIS® abatement system has “rated values” of efficiency up to 90% for H2S and 95% for Hg. Starting from the …

    View paper: Assessment of Geothermal Power Plants Impact on Air Quality – Effect of H2S Abatement with AMIS in the Larderello-Travale-Radicondoli Geothermal Area (Tuscany). PDF: Assessment of Geothermal Power Plants Impact on Air Quality – Effect of H2S Abatement with AMIS in the Larderello-Travale-Radicondoli Geothermal Area (Tuscany). (453 KB)

  12. Unit 14 / Sulphur Springs H2S Abatement Process Screening and Stretford Improvements Study--Part 3

    Benn, Brian; McIntush, Kenneth E.; Beitler, Carrie Ann M.; Mamrosh, Darryl L.; Hileman, O. E. · Geothermal Resources Council Transactions · 2012 ·Effluent abatement; Hydrogen sulfide; Equipment design; Scru

    … The major goal of the study was to improve the primary H2S abatement system at the Sulphur Springs (Unit 14) Power Plant owned by Calpine Corporation and located at The Geysers. The existing Stretford system is approximately 30 years old and is now …

    View paper: Unit 14 / Sulphur Springs H2S Abatement Process Screening and Stretford Improvements Study--Part 3 Download unavailable

  13. Screening of H2S Abatement Options for Geothermal Power Noncondensable Gas at Bjarnarflag

    Mamrosh, Darryl L.; McIntush, Kenneth E.; Beitler, Carrie; Markusson, Sigurdur H.; Einarsson, Kristjan · Geothermal Resources Council Transactions · 2012 ·Hydrogen sulfide; NCG; Effluent abatement

    Non-condensable gas H2S abatement technologies were screened – based on capital and operating costs and some other factors – for implementation at new geothermal power production locations at Bjarnarflag, Iceland. Many technologies exist for removing H2S from …

    View paper: Screening of H2S Abatement Options for Geothermal Power Noncondensable Gas at Bjarnarflag Download unavailable

  14. Injection of H2S from Hellisheiði Power Plant, Iceland

    Ingvi Gunnarsson, Bergur Sigfússon, Andri Stefánsson, Stefán Arnórsson, Samuel Warren Scott and Einar Gunnlaugsson · Stanford Geothermal Workshop · 2011 ·Injection

    … Power Plant annually emits around 13000 tons of H2S into atmosphere. Under certain weather conditions the hydrogen sulfide from the power plant reaches nearby towns and cities, annoying the inhabitants. Reykjavík Energy is preparing injection of …

    View paper: Injection of H2S from Hellisheiði Power Plant, Iceland PDF: Injection of H2S from Hellisheiði Power Plant, Iceland (546KB)

  15. Unit 14 / Sulphur Springs H2S Abatement Process Screening and Stretford Improvements Study -- Part 2

    Benn, Brian; McIntush, Kenneth E.; Beitler, Carrie Ann M.; Mamrosh, Darryl L.; Hileman, O. E. · Geothermal Resources Council Transactions · 2011 ·NCG; Hydrogen sulfide; Air quality; Power plant design and o

    … The major goal of the study was to improve the primary H2S abatement system at the Sulphur Springs (Unit 14) Power Plant owned by Calpine Corporation and located at The Geysers. The existing Stretford system is approximately 30 years old and is now …

    View paper: Unit 14 / Sulphur Springs H2S Abatement Process Screening and Stretford Improvements Study -- Part 2 Download unavailable

  16. Unit 14 / Sulphur Springs H2S Abatement Process Screening and Stretford Improvements Study--part 1

    Benn, Brian; McIntush, Kenneth E.; Beitler, Carrie Ann M.; Mamrosh, Darryl L.; Hileman, O. E. · Geothermal Resources Council Transactions · 2010 ·Hydrogen sulfide

    … three part study performed in 2007 to improve the primary H2S abatement system at Sulphur Springs Unit 14 Power Plant owned by Calpine Corporation and located at The Geysers. The existing Stretford system is approximately 30 years old and under-loaded due …

    View paper: Unit 14 / Sulphur Springs H2S Abatement Process Screening and Stretford Improvements Study--part 1 Download unavailable

  17. Geysers Power Plant H2S Abatement Update

    Farison, John; Benn, Brian; Berndt, Brian · Geothermal Resources Council Transactions · 2010 ·Hydrogen sulfide

    H2S emissions were a major obstacle during development of The Geysers Geothermal Field. H2S abatement systems have evolved over the years and successful H2S abatement to meet stringent air quality standards has become routine. The primary abatement systems …

    View paper: Geysers Power Plant H2S Abatement Update Download unavailable

  18. H2S Concentration in Geothermal and Hydrothermal Fluids - a New Gas Geothermometer

    Nigel J.F. Blamey · Stanford Geothermal Workshop · 2006 ·Geochemistry

    … are based on the CO2-CH4-H2-H2O system but none involve H2S, a gas that is always present in geothermal systems. The equilibrium reactions for water-magnetite-pyrite-pyrrhotite-H2S-CO2-CH4 were first described by Norman et al. (1998) to explain …

    View paper: H2S Concentration in Geothermal and Hydrothermal Fluids - a New Gas Geothermometer PDF: H2S Concentration in Geothermal and Hydrothermal Fluids - a New Gas Geothermometer (159KB)

  19. H2S Monitoring and Emission Control at the Cerro Prieto Geothermal Field, Mexico

    Hector G. Puente and Lourdes Hernandez · World Geothermal Congress · 2005 ·2. Environmental and Societal Aspects

    … monitored ambient air concentrations of hydrogen sulfide (H2S) in the geothermal field as well as in the neighbor villages around the CPGF. Environmental regulations have been reinforced in many countries for air quality emissions. In this particular case, …

    View paper: H2S Monitoring and Emission Control at the Cerro Prieto Geothermal Field, Mexico PDF: H2S Monitoring and Emission Control at the Cerro Prieto Geothermal Field, Mexico (446KB)

  20. Geothermal Steam Economic H2S Abatement and Sulfur Recovery

    Wayne Monnery · World Geothermal Congress · 2005 ·2. Environmental and Societal Aspects

    … as a result, the geothermal steam industry has a need for H2S abatement technology that is suitable and economic for use in geothermal steam facilities. Current technology has proven to have high capital and/or operating costs and some processes are …

    View paper: Geothermal Steam Economic H2S Abatement and Sulfur Recovery PDF: Geothermal Steam Economic H2S Abatement and Sulfur Recovery (89KB)

  21. Yanaizu-Nishiyama Geothermal Power Station H2S Abatement System

    Kazuo Takahashi and Mituru Kuragaki · World Geothermal Congress · 2000 ·Environmental and Social Aspects

    … using air sampling bags and continuous hydrogen sulfide (H2S) monitoring equipment. The source of the odor was identified as the H2S that was released from our geothermal station at a very low concentration range of 6-60 ppb. Based on the results of an …

    View paper: Yanaizu-Nishiyama Geothermal Power Station H2S Abatement System PDF: Yanaizu-Nishiyama Geothermal Power Station H2S Abatement System (1 KB)

  22. H2S Abatement in the Cold Gas Cap of Geothermal Wells Before Kick-Off Tests

    Giorgio Culivicchi, A. Lenzi, R. Perini and B. Tarquini · World Geothermal Congress · 2000 ·Environmental and Social Aspects

    A new system for in-well H2S abatement before kick-off tests has been developed. In this process, the H2S present in the cold gas cap in the upper portion of the well is removed by treating the gas with a hydrogen peroxide solution at neutral pH. The reactant …

    View paper: H2S Abatement in the Cold Gas Cap of Geothermal Wells Before Kick-Off Tests PDF: H2S Abatement in the Cold Gas Cap of Geothermal Wells Before Kick-Off Tests (946 B)

  23. H2s Dispersion Model at Cerro Prieto Geothermoelectric Power Plant

    Ricardo Gallegos-Ortega, Margarito Quintero-Nunez and O. Rafael Garcia-Cueto · World Geothermal Congress · 2000 ·Environmental and Social Aspects

    The concentration levels of H2S in the atmosphere produced by the geothermal production activities at Cerro Prieto Geothermal power plant, located 30 km south to the city of Mexicali, Baja California, Mexico, are studied. By using the compilation and analysis …

    View paper: H2s Dispersion Model at Cerro Prieto Geothermoelectric Power Plant PDF: H2s Dispersion Model at Cerro Prieto Geothermoelectric Power Plant (204 B)

  24. Development of a Safer and More Efficient Method for Abatement of H2S during Geothermal Well Drilling

    Hirtz, Paul; Mac Phee, Tom · Geothermal Resources Council Transactions · 1989 ·Drilling; Environmental aspects; Hydrogen sulfide; Air quali

    … safer, more efficient and cost effective way of abating H2S emissions during well drilling operations at the Geysers is presented in this paper. In 1985, GEO Operator Corporation (GEOOC) commenced with a research program to study the present H2S abatement …

    View paper: Development of a Safer and More Efficient Method for Abatement of H2S during Geothermal Well Drilling Download unavailable

  25. Operating Experiences of Converting a Stretford to a LO-CAT(R) H2S Abatement System at Pacific Gas and Electric Company's Geysers Unit 15

    Henderson, J. M.; Dorighi, Gary P. · Geothermal Resources Council Transactions · 1989 ·Effluent abatement; Hydrogen sulfide; Power plant design and

    … Gas and Electric Company (PG&E) converted the Stretford H2S abatement system at Unit 15 to use LOCAT H2S liquid redox process chemistry. The Stretford process is a vanadium based aqueous phase H2S scrubbing system, while the LOCAT technology uses a …

    View paper: Operating Experiences of Converting a Stretford to a LO-CAT(R) H2S Abatement System at Pacific Gas and Electric Company's Geysers Unit 15 Download unavailable

1 2 3 … 6 Next ›

Papers are freely accessible. Copyright remains with the authors and conference organisers as stated on each paper.

IGA Conference Paper Database · New search