Record Details

Title Operational Challenges and Results from an Experimental One Kilowatt Organic Rankine Cycle
Authors R. Wijninckx, S. Krumdieck
Year 2016
Conference New Zealand Geothermal Workshop
Keywords Experimental Organic Rankine Cycle, ORC, Scroll expander, System Performance, Power generation from waste heat, Zeotropic mixture, M1.
Abstract Organic Rankine Cycle (ORC) systems are capable of utilising low-enthalpy heat sources to generate power. For the performance engineering of ORC systems, it is important to understand process parameters and component behaviour. To maximise performance, modelling of the plant thermodynamics must be coupled with data analysis to develop diagnostic procedures, find optimal operating points, and diagnose problems to schedule the most cost effective maintenance. An existing ORC system at the University of Canterbury has been upgraded from a previous iteration to assist in furthering our knowledge of ORC system design and construction.
This paper presents experimental results from running a 1 kW ORC system using HFC-M1 refrigerant, a zeotropic mixture of R245fa and R365mfc, as the working fluid under a wide range of operating conditions. Hot exhaust combustion products from a 30kW CapstoneTM Gas Turbine are used as the heat source and heat is transferred via a thermal oil loop to the working fluid through a plate heat exchanger. A scroll expander magnetically coupled to an AC generator is used for work extraction and energy conversion. Trials focused on off-design performance, and investigated the effect of varying the refrigerant volume ratio on system performance. Trials were prematurely ended by bearing failure in the expander. A comparative study was performed between the system actual performance and the theoretical performance to evaluate the degree of impact of the operational issues on the system performance. The unit was disassembled to evaluate the component compatibility and assess functionality over the operation. The system mass was not conserved during the operation due to leakage, contributing to the overall deterioration in system performance over time.
Back to Results Download File