World Geothermal Congress · 8. Geochemistry

Total Silica Analysis Using a Double Beam Atomic Absorption Spectrophotometer

Perfecto G. Lim

Abstract

Total silica in geothermal brine when diluted to concentrations less than 100 mg/l and acidified to pH 2.0 or less right after sampling will remain in solution as monomeric silica (Iler, 1978). Experimental runs using atomic absorption spectrophotometry (AAS) in analyzing total silica from geothermal brine was done at Southern Negros Geothermal Production Field (SNGPF) laboratory since 1998. The results were then compared with runs using UV-Visible spectroscopy, which is the standard method adopted by all PNOC-EDC laboratories. This study aims to obtain percent difference of less than 5% with the colorimetric method (UV-ViS) in terms of ppm result. Comparatively the alternative method is cheaper and faster compared with the traditional technique. Repeatable results can be obtained within several minutes to an hour upon sample receipt. Between 2002 to 2003 SNGPF laboratory have used the method of AAS for analyzing total silica. The method was also used in the 2003 IAEA water inter-lab consisting of medium and highly saline brine waters. The results passed for both water types. Optimum instrument settings and stable current is a must for attaining quality results.

Details

Conference
World Geothermal Congress
Year
2005
Session
8. Geochemistry (71 papers)
Paper number
0812
Language
English
Copyright
International Geothermal Association
Keywords
silica analysis atomic absorption spectrophotometer Philippines
Record ID
910

Suggested citation

Perfecto G. Lim (2005). Total Silica Analysis Using a Double Beam Atomic Absorption Spectrophotometer. Proceedings, World Geothermal Congress 2005, Paper 0812.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Lim ›