Silica Inhibitor Hot Injection Test at Bacman Geothermal Production Field, Botong, Philippines

Fidel S. See

Abstract

A series of pilot tests were conducted at the Bacman Geothermal Production Field, Philippines, in order to determine the effectiveness of the current silica inhibitor under hot injection conditions. A representative portion of the inhibitor-treated brine was diverted into a series of insulated one-half inch pipes, with retention vessels connected at the end. The test fluid’s velocity, retention time, and flow regime were set to mimic the brine’s characteristics during the actual hot injection scheme. Results of the latest test showed that at the current inhibitor concentration, dosing rate, brine chemistry, and Fluid Collection and Recycling System (FCRS) parameters, the predicted maximum deposition rate is 20 mm per year along the pipes, and an average of 54 mm per year inside the wellbore. The results indicate that a hot brine injection scheme is technically feasible.

Details

Conference
World Geothermal Congress
Year
2010
Session
27. Corrosion and Scaling (41 papers)
Paper number
2722
Language
English
Geographic area
Bacon-Manito, Philippines; Luzon
Copyright
International Geothermal Association
Keywords
silica inhibition pilot test hot injection
Record ID
6551

Suggested citation

Fidel S. See (2010). Silica Inhibitor Hot Injection Test at Bacman Geothermal Production Field, Botong, Philippines. Proceedings, World Geothermal Congress 2010, Paper 2722.