The steamfield production piping size for the Kawerau geothermal power plant was determined by using predicted well performance and decline rates. The final steamfield configuration used six production wells. The design optimization was based on the test data from four wells, which was extrapolated to include both “normal” and “big bore” wells. A method of using the predicted well performance to determine the influence on steamfield piping size is reviewed. The method takes into account capital cost and make-up well drilling, and how this impacts net present value.

Details

Conference
World Geothermal Congress
Year
2010
Session
25. Production Engineering and Steam Gathering Systems (12 papers)
Paper number
2513
Language
English
Geographic area
Kawerau, New Zealand; Taupo Volcanic Zone
Copyright
International Geothermal Association
Keywords
Steamfield conceptual design RPF SAGS pipe size optimization
Record ID
6479

Suggested citation

Michael Rock (2010). Kawerau Steamfield Design. Proceedings, World Geothermal Congress 2010, Paper 2513.

Proceedings-level reference. Individual papers do not carry DOIs.