Iceland Geothermal Conference · Drilling and Production

Silica scaling: The main obstacle in efficient use of high-temperature geothermal fluids

Ingvi Gunnarsson and Stef??n Arn??rsson

Download PDF (55K)

Abstract

Utilization of geothermal resources involves cooling of the geothermal fluid by extraction of heat from it. In the case of high-temperature geothermal fluids, precipitation of amorphous silica from solution to form silica scales is the main obstacle for efficient heat extraction. The silica scale formation causes operational problems and may even clog pipelines and injection drill holes. The rate of silica scale formation can be reduced by aging amorphous silica over-saturated waters, which allows the aqueous silica inexcess of saturation to polymerize. Polymeric silica has lesser tendency to precipitate from solution than monomeric silica. Studies of separated water from the Nesjavellir geothermal power station, Iceland, indicate that silica scale formation can be avoided during heat extraction by rapid cooling in թ-capillary heat exchangersթ…. Scale formation from the amorphous silica over-saturated water leaving the heat exchanger, which is to be injected, can then be eliminated by aging the water for one to two hours andsubsequently mixing it with condensed steam.

Details

Conference
Iceland Geothermal Conference
Year
2003
Session
Drilling and Production
Language
English
Geographic area
Nesjavellir, Iceland; Hengill, Iceland
Copyright
Geothermal Association of Iceland
Keywords
silica polymerization scaling injection.
Record ID
545

Suggested citation

Ingvi Gunnarsson and Stef??n Arn??rsson (2003). Silica scaling: The main obstacle in efficient use of high-temperature geothermal fluids. Proceedings, Iceland Geothermal Conference 2003.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Gunnarsson ›