Iceland Geothermal Conference · Plant Management

Geochemical monitoring of the response of geothermal reservoirs to production load թ՞ examples from Krafla, Iceland

Stef??n Arn??rsson and Bj??rn Th. Gudmundsson

Abstract

Monitoring of the chemical composition of water and steam discharged from wells in exploited geothermal fields provides information on the response of the reservoir to the production load. Decrease in the Cl concentration in the discharged water indicates relative increase in recharge into producing aquifers of colder water but an increase in Cl indicates recharge from hotter zones. When a well discharge consists of components with different source temperatures, the consequence is discrepancy between geothermometry temperatures. The cause of discrepancy may also be variable departure from equilibrium for individual geothermometers.

Details

Conference
Iceland Geothermal Conference
Year
2003
Session
Plant Management
Language
English
Geographic area
Krafla, Iceland
Copyright
Geothermal Association of Iceland
Keywords
geochemical monitoring response to production geothermometers recharge.
Record ID
505

Suggested citation

Stef??n Arn??rsson and Bj??rn Th. Gudmundsson (2003). Geochemical monitoring of the response of geothermal reservoirs to production load թ՞ examples from Krafla, Iceland. Proceedings, Iceland Geothermal Conference 2003.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Arn??rsson ›