World Geothermal Congress · SECTION 12 - Advanced Technologies (HDR - Magma - Geopressur

A Borehole Simulation Autoclave for Logging Tool Testing at HDR Environment

Paul Hegemann and Fritz Rummel

Download PDF

Abstract

A high-pressure high temperature autoclave system was developed to permit testing of newly designed logging tools under hostile HDR geothermal environmental conditions. autoclave has the following specifications: - inside diameter: - inside length: - max. operating pressure: - max .temperature: - pressure medium: fluids 165mm 7800 (307") 150 (21750 psi) 200 (392 Pressure and temperature can be held constant within 1 per cent of their maximum values. The autoclave has an inside mounted 7-conductor cablehead and electrical as well as hydraulic inlets outlets at various positions to allow tool operation of almost any kind during testing.

Details

Conference
World Geothermal Congress
Year
1995
Session
SECTION 12 - Advanced Technologies (HDR - Magma - Geopressur (38 papers)
Paper number
4-Hegemann
Language
English
Copyright
International Geothermal Association
Keywords
boreholes autoclave logging tool testing HDR
Record ID
4904

Suggested citation

Paul Hegemann and Fritz Rummel (1995). A Borehole Simulation Autoclave for Logging Tool Testing at HDR Environment. Proceedings, World Geothermal Congress 1995, Paper 4-Hegemann.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Hegemann ›