World Geothermal Congress · SECTION 6 - Resource Evaluation and Modeling

Numerical Modeling of the High-Temperature Two-Phase Reservoir at Uenotai Geothermal Field, Akita Prefecture, Japan

M. Pham, S.K. Sanyal, A.J. Menzies, T. Naka, R. Takeuchi and S. Iwata

Download PDF

Abstract

A three-dimensional, integrated finite-difference numerical model was developed to forecast the behavior of the geothermal reservoir supplying a 27.5 MW development at Uenotai in Japan. The model was calibrated in two stages: (1) by matching the initial-state temperature distribution of the field; and (2) by matching enthalpy and flow rate transient histories from a number of wells. Reservoir behavior was forecasted under various scenarios. The results obtained from these forecasts indicate that the reservoir can provide enough steam for the 27.5 power plant for 30 years with the drilling of two additional make-up production wells.

Details

Conference
World Geothermal Congress
Year
1995
Session
SECTION 6 - Resource Evaluation and Modeling (41 papers)
Paper number
3-pham
Language
English
Geographic area
Uenotai, Japan
Copyright
International Geothermal Association
Keywords
numerical modeling high temperature two-phase initial-state history-matching forecasts
Record ID
4806

Suggested citation

M. Pham, S.K. Sanyal, A.J. Menzies, T. Naka, R. Takeuchi and S. Iwata (1995). Numerical Modeling of the High-Temperature Two-Phase Reservoir at Uenotai Geothermal Field, Akita Prefecture, Japan. Proceedings, World Geothermal Congress 1995, Paper 3-pham.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Pham ›