Methods and theory of fumarole measurements are reviewed and the settings of representative surveys are discussed with reference to some data from the Karapiti fumarole field (NZ) collected during the past 50 years. In almost all cases there is disturbance by some inflow of air which becomes entrained in the turbulent steam jet. Reproducible measurements of the heat output of fumarole jets can be obtained where a jet is funnelled through a vertical pipe or where data are collected across the face of an exposed vent. Systematic errors occur where measurements are made at the ground level of 'crater fumaroles' above a steam vent. The output of inaccessible fumaroles can be estimated from plots of the heat output of accessible fumaroles versus normalised steam cloud area visible in air photos. The last method is suitable for monitoring long term changes in the heat output of fumarole fields occurring over many hydrothermal systems.

Details

Conference
World Geothermal Congress
Year
2000
Session
Environmental and Social Aspects (37 papers)
Paper number
R0862
Language
English
Copyright
International Geothermal Association
Keywords
fumaroles steam vents steam flow rates heat flow thermodynamic properties steam cloud area
Record ID
4371

Suggested citation

Manfred P. Hochstein and Christopher John Bromley (2000). Fumarole Measurements Over Hydrothermal Systems. Proceedings, World Geothermal Congress 2000, Paper R0862.