World Geothermal Congress · Production Engineering, Steam Gathering Systems

Steam Flow Measurements in the Maibarara Geothermal Field: A Case Study Between Flow Testing and Online Steam Flowmeters

Ray Francisdeo C. ROMEY, Kennard M. MATURGO, Philip Q. TIZON, Ian L. MENDIVIL, Miguel B. ESBERTO

Abstract

Two types of steam flowmeters are used in the Maibarara Geothermal Field. The vortex flow meter, installed at the main steam line, measures the total steam flow from the separator while the orifice flow meter, installed at the interface, measures the steam flow going into the steam turbine. Periodic flow testing measurements such as tracer flow test (TFT) and horizontal discharge testing are also being conducted. This paper presents a comparison between flow testing and online steam flowmeters using the Bland-Altman analysis to determine the degree of agreement between two steam flow measurement methods. Results show that the vortex and orifice flow meters can substitute for TFT measurements at the main steam line and interface, respectively.

Details

Conference
World Geothermal Congress
Year
2020
Session
Production Engineering, Steam Gathering Systems (42 papers)
Paper number
25014
Language
English
Copyright
International Geothermal Association
Keywords
Maibarara steam flow measurement vortex flowmeter orifice flowmeter tracer flow testing horizontal discharge testing Bland-Altman analysis degree of agreement
Record ID
34192

Suggested citation

Ray Francisdeo C. ROMEY, Kennard M. MATURGO, Philip Q. TIZON, Ian L. MENDIVIL, Miguel B. ESBERTO (2020). Steam Flow Measurements in the Maibarara Geothermal Field: A Case Study Between Flow Testing and Online Steam Flowmeters. Proceedings, World Geothermal Congress 2020, Paper 25014.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Romey ›