World Geothermal Congress · Production Engineering, Steam Gathering Systems
Steam Flow Measurements in the Maibarara Geothermal Field: A Case Study Between Flow Testing and Online Steam Flowmeters
Abstract
Two types of steam flowmeters are used in the Maibarara Geothermal Field. The vortex flow meter, installed at the main steam line, measures the total steam flow from the separator while the orifice flow meter, installed at the interface, measures the steam flow going into the steam turbine. Periodic flow testing measurements such as tracer flow test (TFT) and horizontal discharge testing are also being conducted. This paper presents a comparison between flow testing and online steam flowmeters using the Bland-Altman analysis to determine the degree of agreement between two steam flow measurement methods. Results show that the vortex and orifice flow meters can substitute for TFT measurements at the main steam line and interface, respectively.
Details
Suggested citation
Ray Francisdeo C. ROMEY, Kennard M. MATURGO, Philip Q. TIZON, Ian L. MENDIVIL, Miguel B. ESBERTO (2020). Steam Flow Measurements in the Maibarara Geothermal Field: A Case Study Between Flow Testing and Online Steam Flowmeters. Proceedings, World Geothermal Congress 2020, Paper 25014.
Proceedings-level reference. Individual papers do not carry DOIs.