World Geothermal Congress · Reservoir Engineering
Use the Software Wellsim® to Determine the Causes of the Decline in Production H-1D Well After Mechanical and Chemical Cleaning of the Los Humeros (Mexico) Geothermal Field
Abstract
Due to the decline in production from H-1D well on the Los Humeros Geothermal Field (HGF) caused by the deposition of calcite and silica inside of the pipes and the annular area between the slotted liner and hole 8,5”, it was subject to mechanical and chemical cleaning between June and July 2010. The results were successful and the increase in production was 766%. However, the well production drop drastically in the evaluation stage to a similar production measured before acid stimulation. To understand the phenomenon occurred in the well, analysis of the chemical and thermodynamic information of the fluid saturation indices, go devils was performed. Additionally the mechanisms of production into the well were analyzed; comparing the data obtained with the simulated data scenarios before the stimulation job using the simulation software Wellsim®. In this paper, the analysis of causes of the decline production in H-1D Well in the Los Humeros Geothermal Field is presented.
Details
Suggested citation
Magaly FLORES, Miguel RAMIREZ, Lilibeth MORALES (2015). Use the Software Wellsim® to Determine the Causes of the Decline in Production H-1D Well After Mechanical and Chemical Cleaning of the Los Humeros (Mexico) Geothermal Field. Proceedings, World Geothermal Congress 2015, Paper 22021.
Proceedings-level reference. Individual papers do not carry DOIs.