Abstract

The capital cost for a representative binary plant using hydrocarbon working fluid and rejecting heat with a cooling tower is $1775/KW of net power output. The cost of a comparable ammonia plant is $1450/KW. If a spray pong is used instead of a cooling tower the cost is reduced to $1250/KW. These costs do not include the wells, geofluid pumps, and piping which will add an additional $300/KW.

Details

Conference
Geothermal Resources Council Transactions
Year
1991
Session
Economics; Binary cycle power generation; Working fluids; Po
Language
English
Copyright
Geothermal Resources Council
Keywords
Economics Power Generation USA Binary Systems Working Fluid Financing Operating Costs Efficiency Power Plant Design Turbine Design Cooling Towers Isobutane Pilot Projects Capital Cost Ammonia Plant Hydrocarbon Comparative Evaluations
Record ID
16249

Suggested citation

Forsha, Michael D.; Nichols, Kenneth E. (1991). Factors Affecting the Capital Cost of Binary Power Plants. Proceedings, Geothermal Resources Council Transactions 1991.