Geothermal Resources Council Transactions · Binary cycle power generation; Computer modeling; Power plan

Operational Upset Transients in a Dual Boiling Binary Cycle Geothermal Power Plant

Wiggins, D. J.; Bliem, C. J.

Download unavailable for this file.

Abstract

The effects of operational upsets (such as a value or pump failure) on a dual boiling binary power plant with isobutane as the working fluid are discussed. These results are based on a mathematical simulation using vendor specifications of the existing components and materials in the 5MW(e) Raft River Pilot Plant. The major problems which can result are excessive heat up or cool down rates in the heat exchangers and reverse flow into lower pressure areas. Effects of upsets on plant operation are discusses and appropriate counteractive operator action is recommended.

Details

Conference
Geothermal Resources Council Transactions
Year
1980
Session
Binary cycle power generation; Computer modeling; Power plan
Language
English
Copyright
Geothermal Resources Council
Keywords
Power Generation Dual boiling Binary cycle Isobutane Problem simulation Operation Bypass valve
Record ID
14785

Suggested citation

Wiggins, D. J.; Bliem, C. J. (1980). Operational Upset Transients in a Dual Boiling Binary Cycle Geothermal Power Plant. Proceedings, Geothermal Resources Council Transactions 1980.