Geothermal Resources Council Transactions · Power plant design and operation; Single flash; Dual flash;

Heat Balance and Optimum Flashing Pressures for the Fifth Unit of Cerro Prieto

Reza, Jorge A.

Download unavailable for this file.

Abstract

A computer program has been develop to calculate the heat balance and to optimize the electric generation both for one and two stages of flashing, for the fifth geothermal unit of Cerro Prieto, Mexico. The 3000 t/hr of separated brine from units 1 to 4, which as the present time are being rejected to waste, are to be utilized in a flash power cycle, in an optimum manner. Two alternatives were presented: (a) a single stage flash cycle with a maximum generation of 24 MW net and flash pressure of 30 psia and (b) dual stage flash cycle with maximum generation of 27.5 MW and corresponding pressures 30,62 psia. Although the thermodynamics maximum is obtained for much lower pressures, scaling would cause serious damages to the surface equipment.

Details

Conference
Geothermal Resources Council Transactions
Year
1979
Session
Power plant design and operation; Single flash; Dual flash;
Language
English
Geographic area
Cerro Prieto, Mexico
Copyright
Geothermal Resources Council
Keywords
Power Plant Design Power Generation Mexico Salton Trough Cerro Prieto Single Flash Cycle Study Design Optimization Computer Model Thermodynamics IIE
Record ID
14586

Suggested citation

Reza, Jorge A. (1979). Heat Balance and Optimum Flashing Pressures for the Fifth Unit of Cerro Prieto. Proceedings, Geothermal Resources Council Transactions 1979.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by Reza, Jorge A. ›