World Geothermal Congress · Country Updates
Analyze of Tajikistan's Geothermal Resources and Implementation of Ground Source Heat Pumps
Abstract
This study focuses on two areas: analyzing Tajikistan's geothermal resources using modern methods; implementing ground source heat pumps (GSHP) in the Dushanbe artesian basin. Through the efforts of scientists from different countries in the last century, extensive geological, hydrological, geophysical and geochemical studies were carried out in Tajikistan. As a result of numerous scientific expeditions, maps of geothermal fields were compiled, that form the basis of scientific research in this area today. Out of the 28 largest thermal springs, 8 are located in Central Tajikistan, and 20 in the high-mountainous Pamirs. The total resource of the geothermal sources identified to date is 151 million kWh per year, which corresponds to a capacity of 17.2 MW. Based on some of these sources (Khoja Obi Garm (98℃), Dzhilandy (67.5℃), Garm Chashma (60℃), Khovatag (55℃), Obi Garm (53℃), Yamchun (43℃), Yavroz (42℃), Avdzh (34℃)) centers of health, recreation, balneology and tourism are organized. The rest of the sources are used to heat the homes of local residents and greenhouses. It should be noted that deep geothermal springs (more than 200 m deep) have much higher energy and can be used as sources of electricity. Unfortunately, at the moment, the country lacks a developed base of deep well drilling technologies. This study also assesses the suitability of the Dushanbe artesian basin for large-scale implementation of geothermal heat pumps (GHPs). Based on field tests of thermal response (TRT), laboratory measurements, and hydrochemical analysis of groundwater, a comprehensive assessment of the thermophysical and chemical parameters of the environment was carried out. The results indicate that the average effective thermal conductivity of the soil is 1.9 W/(m·K), and the stable temperature of the subsoil is maintained at 16.5 °C, confirming the region's high potential for geothermal systems. Hydrochemical analysis revealed a correlation between electrical conductivity (EC) and total hardness, as well as increased risks of carbonate deposition in closed circulation loops. Modeling results showed that using grouting mixtures with an increased quartz sand content can increase the heat output of a borehole heat exchanger by up to 20%.
Details
Suggested citation
Mamadsho Ilolov, Fumiaki Inagaki, Jamshed Sh. Rahmatov, Ahmadsho M. Ilolov, Sakina M. Karimova (2026). Analyze of Tajikistan's Geothermal Resources and Implementation of Ground Source Heat Pumps. Proceedings, World Geothermal Congress 2026.
Proceedings-level reference. Individual papers do not carry DOIs.