World Geothermal Congress

Evaluation of Thermal Interference between Horizontal Ground Heat Exchangers

Takahiro Ogawa, Hikari Fujii, Retsu Harada, Hiroyuki Kosukegawa, Saeid Mohammadzadeh Bina

Download PDF

Abstract

Ground Source Heat Pump (GSHP) systems using vertical Ground Heat Exchangers (GHEs) are costly to install in Japan due to complex geological conditions. As a cost-effective alternative, Horizontal GHEs (HGHEs) can be installed at shallow depths using Horizontal Directional Drilling (HDD). However, HGHEs require large land areas, which limits their feasibility in land-scarce regions. HDD offers a viable solution for installing HGHEs in space-constrained environments. Nevertheless, thermal interference between adjacent GHEs can reduce system performance, making its investigation important for optimal design. In this study, field experiments were conducted in Saga City, Japan, to examine thermal interference between HDD-installed HGHEs spaced at 1 m, 2 m, and 4 m intervals. Thermal Response Tests (TRTs) were performed for each spacing scenario, confirming that greater distance between GHEs reduced thermal interference and improved heat exchange performance. A numerical model was then developed using FEFLOW based on geological conditions and was validated using measured temperatures at the turning and outlet points of the GHEs. The validated model was used to conduct long-term cooling simulations at GHE distances of 1 m, 2 m, and 4 m, respectively. As a result, thermal interference was observed on the 12th and 40th day after the start of the simulation at 1 m and 2 m spacing. Additionally, the predicted temperature difference between 1 m and 4 m spacing was only 0.6°C after 4 months, indicating that in GSHP systems with two HGHEs, the influence of thermal interference on overall energy efficiency is relatively small.

Details

Conference
World Geothermal Congress
Year
2026
Paper number
578864
Copyright
World Geothermal Congress 2026
Keywords
ground source heat pump horizontal ground heat exchangers horizontal directional drilling numerical simulation thermal response test thermal interference
Record ID
1000154

Suggested citation

Takahiro Ogawa, Hikari Fujii, Retsu Harada, Hiroyuki Kosukegawa, Saeid Mohammadzadeh Bina (2026). Evaluation of Thermal Interference between Horizontal Ground Heat Exchangers. Proceedings, World Geothermal Congress 2026, Paper 578864.

Proceedings-level reference. Individual papers do not carry DOIs.

More papers by OGAWA ›