Der Geothermiekongress
Geothermal Digital Twins
Abstract
Maximising nett energy output of a geothermal system is essential to make geothermal energy
successful. A Digital Twin of the system is an effective tool to optimise the performance and to gain
control on well integrity risks.
This paper presents a digital twin framework for geothermal systems, focusing on two key
challenges for long-term field and assets performance: injectivity and well integrity. Injectivity
decline, caused by reservoir changes, scaling, and operational conditions, reduces operational
efficiency, while incremental injectivity may occur due to factors like temperature effects.
The injectivity monitoring application of the digital twin includes real-time calculation of the injectivity
index. Moreover, Hall and skin factor plots are presented to enables scenario analysis in addition to
the real-time monitoring. As a result, a decline in injectivity, due to scaling issues, is reflected in a
decreasing injectivity index, an increased skin factor and a deviation of the Hall derivative from the
Hall plot showing a steeper positive slope.
Well Integrity Management Systems (WIMS) are becoming mandatory for deep geothermal systems
several countries now. The digital twin can monitor the status of the WIMS compliance. A digital twin
using real-time data and corrosion rate models enables in-time decision making for an optimized
operational scenario and scheduled maintenance preventing expensive repairs, unplanned
downtime or significant shortened well life and reputation damage. The WIMS Dashboard visualises
the well integrity status using a real-time model to determine the corrosions rate. Corrosion rate
predictions are then used to optimize maintenance schedules, adjust the frequency of logging
activities, and facilitate proactive interventions. These predictive models are validated through
physical inspections using calliper logs and coupon samples, providing a feedback loop that
enhances model accuracy and are based on real-time data collection from operational parameters
and corrosion probes, combined with semi-real-time data from fluid chemistry analysis.
In addition to the architecture of the digital twin, a case study will be presented to demonstrate the
effectiveness of the injectivity and corrosion applications. The developed digital twin framework is
being tested on and integrated into a geothermal plant in the Netherlands for direct-use heating
application.
Details
Suggested citation
Geertjan van Og, Floris Degener, Arturs Blinovs, Ryvo Octaviano, Demetris Palochis, Leila Hashemi, Pejman Shoeibi Omrani (2025). Geothermal Digital Twins. Proceedings, Der Geothermiekongress 2025.
Proceedings-level reference. Individual papers do not carry DOIs.