Stanford Geothermal Workshop · Hot Dry Rock

A Downhole Pump Test on a 2km Deep Hot Dry Rock Geothermal System

M.F. Nazroo, T.S. Bennett

Download PDF (483KB) Hosted on pangea.stanford.edu

Abstract

During the continuing long-term circulation programme of the 2 km deep Hot Dry Rock (HDR) geothermal system at Camborne, a downhole pump was installed in the production well and used to investigate the effects of sub-hydrostatic pressure on reservoir performance. This condition is expected to occur naturally in a 6 km deep HDR reservoir. Tracer test results showed a change in the flow distribution but no overall change in the effective circulating volume of the reservoir and this was confirmed by the unchanged thermal behaviour of the reservoir. Although the production flow rate did increase during the test the impedance was also increased and indicated that the increased effective stress acting on the joints close to the production well was causing them to close up.

Details

Conference
Stanford Geothermal Workshop
Year
1989
Session
Hot Dry Rock
Language
English
Geographic area
Cornwall, United Kingdom
Copyright
Stanford Geothermal Program
Record ID
2575

Suggested citation

M.F. Nazroo, T.S. Bennett (1989). A Downhole Pump Test on a 2km Deep Hot Dry Rock Geothermal System. Proceedings, Stanford Geothermal Workshop 1989.