-
Zhu Jialing; Zhang Wei; Liu Guoqiang
·
Geothermal Resources Council Transactions
·
2006
·Direct use; Absorption heat transformer; geothermal waste he
… feasibility of the scheme, utilizing the absorption heat transformer (AHT) to recover the geothermal waste heat by simulating the thermodynamic cycle of the LiBr/H2O AHT. The waste geothermal water at 50° as a driving heat can heat the hot water stream …
View paper: Study of the Type II Absorption Heat Transformer for Utilizing Geothermal Waste Heat
Download unavailable
-
Mohsen TAGHADDOSI, Sohail PORKHIAL
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
… can also be used in some industrial applications. Power Transformers are used in power transmission network in Iran. In the warm months of the year due to high power consumption, the temperature inside the transformer coil increases, and the high …
View paper: Geothermal Heat Pump as a Cooling System to Reduce the Temperature of the Transformer’s Oil
PDF: Geothermal Heat Pump as a Cooling System to Reduce the Temperature of the Transformer’s Oil (811 KB)
-
Dai, Bingjie; Fu, Wencheng
·
Geothermal Resources Council Transactions
·
2014
·Power plant design and operation; Equipment design; Heat tra
An absorption heat transformer (AHT) is proposed in this paper, and the geothermal tail water can be recycled using AHT to decrease the thermal pollution caused by geothermal tail water and increase the power output. In order to study the performance of AHT …
View paper: Theoretical Study on Absorption Heat Transformer Coupled with KCS34 System
Download unavailable
-
Wencheng FU, Chengke NIU, Tailu LI, Jialing ZHU, Wei ZHANG
·
World Geothermal Congress
·
2015
·Power Generation
A novel Kalina cycle coupled absorption heat transformer (KC-AHT) is proposed in this paper. The temperature of geothermal tail water of Kalina cycle, as an example in Husavik, Iceland, is about 80℃, which is used to district heating continue. But for …
View paper: Parametric Optimization and Adaptable Comparison of Power Generation Cycle for Medium- and Low-temperature Geothermal Energy
PDF: Parametric Optimization and Adaptable Comparison of Power Generation Cycle for Medium- and Low-temperature Geothermal Energy (735 KB)
-
Danu S. PURNOMO, Reza ADIPRANA, Eko YUNIARTO, Prihadi S. DARMANTO
·
World Geothermal Congress
·
2015
·Power Generation
… reliability model and failure prediction on generator and transformer. Based on the model, the reliability of generator and transformer has been decrease from its initial condition. Generator has its reliability value of 23%, while the reliability of …
View paper: Reliability Analysis and Improvement Programs of Kamojang Geothermal Power Plant Unit-1
PDF: Reliability Analysis and Improvement Programs of Kamojang Geothermal Power Plant Unit-1 (754 KB)
-
Knox, Lauri A.; Moore, Michael C.
·
Geothermal Resources Council Transactions
·
1990
·Power plant design and operation; Flash steam power generati
The GEO East Mesa power plant and brine field development has design features that are unique in the geothermal industry. These design features include turbine driven brine injection pumps and vertically mounted, horizontally split case, centrifugal pumps …
View paper: Geo East Mesa Geothermal Project: Pumped, Double Flash Technology
Download unavailable