Searches title, authors, abstract, keywords and session. Use "quotes" for an exact phrase.
All filled fields must match. Conference and year are added to the filters on the left.
M. Young, S.J. Zarrouk · New Zealand Geothermal Workshop · 2022 ·Session 3.3 - PRODUCTION & MANAGEMENT 2
… bio-dispersant/biocide and glutaraldehyde biocide for microbiological control. While initially successful, the caustic consumption and expenditure steadily increased over several years. This work presents an updated review of the chemical dosing history …
View paper: Chemical Dosing for Te Mihi Geothermal Station Cooling Towers: Update PDF: Chemical Dosing for Te Mihi Geothermal Station Cooling Towers: Update (535KB)
M. Young and S.J. Zarrouk · New Zealand Geothermal Workshop · 2021 ·Seesion 4.2 - Production and Management 2
… to the understanding and monitoring of the degradation and control mechanisms.
View paper: INVESTIGATION OF COOLING WATER CHEMICAL DOSING: THE OHAAKI GEOTHERMAL POWER STATION COOLING TOWER PDF: INVESTIGATION OF COOLING WATER CHEMICAL DOSING: THE OHAAKI GEOTHERMAL POWER STATION COOLING TOWER (1087KB)
M. Young and S.J. Zarrouk · New Zealand Geothermal Workshop · 2020 ·Session 4.1 Above Ground Technology 2
… sulphur deposition and micro- and macro-biological control in addition to the reservoir steam chemistry. A holistic approach is best when investigating problems to better understand the system and how best to implement solutions. Poihipi Road Power …
View paper: Poihipi Geothermal Power Plant Water Cooling System – Taking a Holistic Approach to Investigating Problems and Implementing Solutions PDF: Poihipi Geothermal Power Plant Water Cooling System – Taking a Holistic Approach to Investigating Problems and Implementing Solutions (1201KB)
M.G. Young · New Zealand Geothermal Workshop · 2018 ·Session 1.2 Geothermal Engineering - Production and Manageme
… in May 2014 but started experiencing cooling water pH control issues after 12 months operation. The alternating dual biocide programme of dosing a quaternary ammonium biodispersant/biocide (quat) one week then glutaraldehyde biocide (glut) the following …
View paper: OPTIMISATION OF CHEMICAL DOSING FOR TE MIHI COOLING TOWERS PDF: OPTIMISATION OF CHEMICAL DOSING FOR TE MIHI COOLING TOWERS (546KB)
T.A. Clark and I.M. Richardson · New Zealand Geothermal Workshop · 2017 ·Session 4.1: Production
… The challenges of corrosion, deposition and biological control can be magnified in systems utilising direct contact condensers due to the presence of hydrogen sulphide in the cooling water. The presence of hydrogen sulphide results in the formation of …
View paper: HYDROGEN PEROXIDE AS A GEOTHERMAL COOLING WATER BIOCIDE PDF: HYDROGEN PEROXIDE AS A GEOTHERMAL COOLING WATER BIOCIDE (790KB)