  1. Online Monitoring of Corrosion in Slightly Saline Geothermal Water in Iceland

    Kristmannsdottir, H.; Thorarinsdottir, R. I.; Sveinbjornsson, A. S.; Jonsdottir, F. · Geothermal Resources Council Transactions · 2012 ·Corrosion; Equipment design; Remote monitoring

    Online monitoring of corrosion is a valuable tool for heating systems to minimize risk of damage due to steel corrosion. Monitoring with weight loss coupons has the limitation that it takes a while to recognize the problem and a great damage may have already …

    View paper: Online Monitoring of Corrosion in Slightly Saline Geothermal Water in Iceland Download unavailable

  2. Development of an Advanced Electrochemical Sensor for Corrosion and Scaling Monitoring in Geothermal Power Plants

    Lorena FREIRE, Julio SÁNCHEZ, Rubén CASTRO, Alberto FERNÁNDEZ · World Geothermal Congress · 2020 ·Corrosion and Scaling

    Corrosion and scaling are the major issues in the exploitation of geothermal sources. Geothermal fluids are very complex mixtures consisting of dissolved gases and high salinity solutions, which creates very aggressive environments. This aggressiveness is …

    View paper: Development of an Advanced Electrochemical Sensor for Corrosion and Scaling Monitoring in Geothermal Power Plants PDF: Development of an Advanced Electrochemical Sensor for Corrosion and Scaling Monitoring in Geothermal Power Plants (800 KB)

  3. Continuous Corrosion and Erosion Monitoring in Geothermal Power Facilities

    Tom FUGGLE · World Geothermal Congress · 2015 ·Corrosion and Scaling

    Continuous measurement presents a step change in monitoring corrosion and erosion, the levels of corrosion rates that can be determined and the accuracy of that determination. Pipework and vessels in geothermal facilities are always at risk of corrosion or …

    View paper: Continuous Corrosion and Erosion Monitoring in Geothermal Power Facilities PDF: Continuous Corrosion and Erosion Monitoring in Geothermal Power Facilities (463 KB)

  4. Simulating and Monitoring of Stress Corrosion Cracking Under Geothermal Steam

    Shirmohamadi, Manuchehr; Ridgely, John; Bloomfield, Kit · Geothermal Resources Council Transactions · 1998 ·Stress corrosion cracking; Turbines

    View paper: Simulating and Monitoring of Stress Corrosion Cracking Under Geothermal Steam Download unavailable

  5. Chemical Treatment Efficiency on Scaling and Corrosion at Rittershoffen, France, Upper Rhine Graben

    Justine MOUCHOT, Guillaume RAVIER, Clio BOSIA, Olivier SEIBEL, Fanny MERCIER, Justine MENGES · World Geothermal Congress · 2020 ·Corrosion and Scaling

    … Graben. By the application of a filming agent acting as corrosion inhibitor, the electrochemical processes leading to lead and arsenic sulphide deposition are significantly reduced, as well as contributing to the tubular heat exchanger, pipes and …

    View paper: Chemical Treatment Efficiency on Scaling and Corrosion at Rittershoffen, France, Upper Rhine Graben PDF: Chemical Treatment Efficiency on Scaling and Corrosion at Rittershoffen, France, Upper Rhine Graben (1128 KB)

  6. Plant Monitoring Techniques and Second Generation Designs

    Kindle, Cecil H.; Shannon, Donald W.; Robertus, Robert J.; Pierce, Debra D.; Sullivan, Robert G. · Geothermal Resources Council Transactions · 1985 ·Scaling; Corrosion; Power plant design and operation; Equipm

    … permits the detection of scaling, the onset of scaling, corrosion loss, current corrosion rates and incipient heat exchanger failure. Conceptual advances are noted which simplify the research techniques to approaches that should be usable even in some low …

    View paper: Plant Monitoring Techniques and Second Generation Designs Download unavailable

  7. Scaling and Corrosion Control in a High Chloride Geothermal Brine

    Keith LICHTI, Rosalind JULIAN, Kevin BROWN, Gener VILLAFUERTE, Richard DAMBE · World Geothermal Congress · 2020 ·Corrosion and Scaling

    … was considered to present an unacceptably high risk of corrosion of carbon steels used for process piping and steam separation plant as well as reinjection wells. Increasing the pH was seen as a viable alternative solution to increase the silica …

    View paper: Scaling and Corrosion Control in a High Chloride Geothermal Brine PDF: Scaling and Corrosion Control in a High Chloride Geothermal Brine (882 KB)

  8. Corrosion and Scaling in High Gas (25wt%) Geothermal Fluids

    Keith A Lichti and Rosalind H. Julian · World Geothermal Congress · 2010 ·27. Corrosion and Scaling

    … fields giving near neutral to alkali chloride waters. Corrosion in the moderate gas geothermal fields has been extensively studied. Corrosion behaviour in high gas geothermal fields such as at Ngawha having up to 10 wt% gas was initially predicted to be …

    View paper: Corrosion and Scaling in High Gas (25wt%) Geothermal Fluids PDF: Corrosion and Scaling in High Gas (25wt%) Geothermal Fluids (653KB)

  9. REAL-TIME TOTAL SUSPENDED SOLIDS (TSS) MONITORING SUITABLE FOR GEOTHERMAL POWER PLANTS

    Evie T. Villarico · Philippine International Geothermal Congress · 2025

    … levels contribute to erosion, scale formation, and pitting corrosion on turbine components. This study evaluated a newly acquired online monitoring system capable of measuring TSS, pH, conductivity, and sodium in real time. Geothermal steam samples were …

    View paper: REAL-TIME TOTAL SUSPENDED SOLIDS (TSS) MONITORING SUITABLE FOR GEOTHERMAL POWER PLANTS PDF: REAL-TIME TOTAL SUSPENDED SOLIDS (TSS) MONITORING SUITABLE FOR GEOTHERMAL POWER PLANTS (7990KB)

  10. Cfd Modelling of Corrosion Test Loops for Geothermal Fluid Applications

    K. Lichti, R. Julian, C. Davies, B. Fletcher, K. Osato, M. Sato, K. Kasai, N. Yanagisawa, K. Sakura · New Zealand Geothermal Workshop · 2020 ·Session 5.2 Above Ground Technology 3

    Small bore corrosion test loops in side streams have been commonly used for many years in the oil and gas industry for cooling water corrosion monitoring. This work describes a high temperature flowing brine test loop for on-line Electrical Resistance, Linear …

    View paper: Cfd Modelling of Corrosion Test Loops for Geothermal Fluid Applications PDF: Cfd Modelling of Corrosion Test Loops for Geothermal Fluid Applications (681KB)

  11. Integrated Fluid-Chemical Monitoring Systems for Geothermal Applications

    Harald MILSCH, Ronny GIESE, Mathias POSER, Simona REGENSPURG, Stefan KRANZ · World Geothermal Congress · 2015 ·Geochemistry

    … might lead to failure of plant components through corrosion and scaling and/or damage the reservoir’s permeability upon fluid reinjection and thus decrease injectivity. Within the fluid loop above ground a number of locations can be defined where …

    View paper: Integrated Fluid-Chemical Monitoring Systems for Geothermal Applications PDF: Integrated Fluid-Chemical Monitoring Systems for Geothermal Applications (1115 KB)

  12. Towards a comprehensive environmental monitoring of a geothermal power plant in the Rhine graben

    Ravier, G; Baujard, C; Dalmais, E; Maurer, V; Cuenot, N · European Geothermal Congress · 2016 ·Technology and Best practice – Environmental Impact

    … purpose of this paper is to present the main environmental monitoring performed during operational phases of a geothermal power plant in the Upper Rhine graben and their associated cost. Five kinds of impacts are identified and monitored from large to local …

    View paper: Towards a comprehensive environmental monitoring of a geothermal power plant in the Rhine graben PDF: Towards a comprehensive environmental monitoring of a geothermal power plant in the Rhine graben (623KB)

  13. Corrosion in the Podhale Geothermal System

    Jacek Banas, Maciej Pawlikowski · International Summer School · 2004

    Geothermal system of Banska

    View paper: Corrosion in the Podhale Geothermal System PDF: Corrosion in the Podhale Geothermal System (371KB)

  14. Geothermal Digital Twins

    Geertjan van Og, Floris Degener, Arturs Blinovs, Ryvo Octaviano, Demetris Palochis, Leila Hashemi, Pejman Shoeibi Omrani · Der Geothermiekongress · 2025

    … WIMS compliance. A digital twin using real-time data and corrosion rate models enables in-time decision making for an optimized operational scenario and scheduled maintenance preventing expensive repairs, unplanned downtime or significant shortened well …

    View paper: Geothermal Digital Twins PDF: Geothermal Digital Twins (974 KB)

  15. Pitting Initiation Detection System for Early Condensate Regime

    Shirmohamadi, Manuchehr; Ridgely, John; Bratt, Shawn · Geothermal Resources Council Transactions · 2000 ·Plant & Field Enhancement; Corrosion; Pitting Initiation; Mo

    View paper: Pitting Initiation Detection System for Early Condensate Regime Download unavailable

Papers are freely accessible. Copyright remains with the authors and conference organisers as stated on each paper.

IGA Conference Paper Database · New search