Wanlong Cai, Fenghao Wang, Chaofan Chen, Yuping Zhang, Yanlong Kong, Zhonghe Pang, Olaf Kolditz, Haibing Shao
·
World Geothermal Congress
·
2023
·Geothermal Heat Pumps
The ground source heat pump is by far the most widely applied technology in geothermal energy utilization. To meet the heating demand in densely populated urban areas, the Deep borehole heat exchanger (DBHE) coupled geothermal heat pump is increasingly being …
View paper: Field Test and Numerical Investigation on Long-term Performance of Deep Borehole Heat Exchanger Coupled Heat Pump Heating System Based on Pilot Projects in Xi’an, China
PDF: Field Test and Numerical Investigation on Long-term Performance of Deep Borehole Heat Exchanger Coupled Heat Pump Heating System Based on Pilot Projects in Xi’an, China (1,1 MB)
-
Pingfang Hu, Zhigao Hu, Na Zhu, Fei Lei, Yiwei Xie
·
World Geothermal Congress
·
2023
·Geothermal Heat Pumps
Based on the test results of some ground source heat pump systems in Wuhan, China, the energy efficiency, operation parameters and indoor thermal environment are studied. Indirect method was used to measure energy efficiency of the heat pump unit and system. …
View paper: The analysis of test results for the operation of some ground coupled heat pump systems in Wuhan
PDF: The analysis of test results for the operation of some ground coupled heat pump systems in Wuhan (0,76 MB)
-
Aidin KAHRABI, Saeed SHAYAMEHR, Fateme MOHAMMADI
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
… in calculating the coil length in geothermal heat pump systems is the value of soil thermal conductivity which can be obtained through different methods. This can greatly affect the excavation and coil installation process and consequently the total …
View paper: Experimental Study on the Impact of Two-Pipe and Four-Pipe Series-Mode Layout on the Heat Transfer in Thermal Response Test for Geothermal Heat Pump Project in Qanavat, Iran
PDF: Experimental Study on the Impact of Two-Pipe and Four-Pipe Series-Mode Layout on the Heat Transfer in Thermal Response Test for Geothermal Heat Pump Project in Qanavat, Iran (1063 KB)
-
Ken Ikeuchi, Shinji Takasugi and Shinichi Miyazaki
·
World Geothermal Congress
·
2000
·Direct Use, Geothermal Heat Pumps
… It is verified that heating by geothermal heat pump (GHP) can be used instead of the current boiler heating in the severe climate condition of Kamchatka. In this report, the GHP test as a part of this F/S investigation result is summarized.
View paper: Hot Water Supply Test Using Geothermal Heat Pump Systems at Petropavlovsk-Kamchatky, the Capital of Kamchatka, Russia
PDF: Hot Water Supply Test Using Geothermal Heat Pump Systems at Petropavlovsk-Kamchatky, the Capital of Kamchatka, Russia (353 B)
-
Hiroyuki KOSUKEGAWA, Hikari FUJII
·
Stanford Geothermal Workshop
·
2019
·Direct Use
In the Ground Source Heat Pump (GSHP) System, it is important to improve the heat exchange rate of ground heat exchangers (GHE) and reduce the initial cost. The Semi-open Loop GSHPs which is proposed in this study, improves the heat exchange capacity by …
View paper: Long-Term Heating Test Using the Semi-open Loop Ground Source Heat Pump System
PDF: Long-Term Heating Test Using the Semi-open Loop Ground Source Heat Pump System (1548 KB)
-
Murat AYDIN, Rolf BRACKE
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
In designing of Ground Source Heat Pumps (GSHP), Thermal Response Tests (TRT) provide a profound basis for the final implementation. With a TRT, the effective thermal conductivity and thermal resistance of a borehole can be obtained. Until today, several TRT …
View paper: Determining Thermal Conductivities of Boreholes by Immersed Probes Using the Constant Temperature Test
PDF: Determining Thermal Conductivities of Boreholes by Immersed Probes Using the Constant Temperature Test (1174 KB)
-
Hiroyuki KOSUKEGAWA, Hikari FUJII
·
World Geothermal Congress
·
2015
·Geothermal Heat Pumps
In ground source heat pump (GSHP) systems, it is important to carry out thermal response tests (TRTs) and estimate the thermal conductivity of the ground with good accuracy for the optimum design of the system. In conventional TRTs, the circulating medium is …
View paper: Development of Thermal Response Test Device with Automatic Control System
PDF: Development of Thermal Response Test Device with Automatic Control System (1058 KB)
-
Hikari Fujii, Hiroaki Okubo, Naokatsu Cho and Kunio Ohyama
·
World Geothermal Congress
·
2010
·29. Geothermal Heat Pumps
… Ground Heat Exchangers (GHEs) on Geothermal Heat Pump (GHP) systems for the use in greenhouse farming. As the type of horizontal GHEs, slinky coils were employed considering the limited land space in Japanese greenhouse farming. Two types of …
View paper: Field Tests of Horizontal Ground Heat Exchangers
PDF: Field Tests of Horizontal Ground Heat Exchangers (539KB)
-
José Acuña, Björn Palm
·
World Geothermal Congress
·
2010
·29. Geothermal Heat Pumps
… of heat exchange with the ground in Ground Source Heat Pumps. Different designs have been discussed and increased interest on innovation within this field has taken place during the last years. This paper presents the first measurement results from a 189 …
View paper: A Novel Coaxial Borehole Heat Exchanger: Description and First Distributed Thermal Response Test Measurements
PDF: A Novel Coaxial Borehole Heat Exchanger: Description and First Distributed Thermal Response Test Measurements (681KB)
-
Burkhard Sanner, Byoung-Youn Choi
·
World Geothermal Congress
·
2005
·14. Direct Use, Geothermal Heat Pumps
An experimental ground source heat pump plant has been installed in 2003 in the city of Daejon, South Korea, in a German-Korean co-operation. Different types of borehole heat exchangers (BHE) with different types of thermally enhanced grout are investigated …
View paper: Ground Source Heat Pump Research in South Korea
PDF: Ground Source Heat Pump Research in South Korea (152KB)
-
Fujii, Hikari; Akibayashi, Satoshi; Ohshima, Kazuo
·
Geothermal Resources Council Transactions
·
2002
·Direct use; Geothermal Heat Pumps; Thermal Response Test; Ho
View paper: Interpretation of Thermal Response Tests in Shallow Deposits
Download unavailable
-
Flynn, Thomas; Larson, Keith
·
Geothermal Resources Council Transactions
·
1983
·Direct use; District heating/cooling; Exploration; Well test
… an aquitard that limits fluid mixing. A series of pump test, completed on CD-1 in February, 1093, indicate that the transmissivity of the thermal aquifer is very high. A pumping rate of 225 gallons per minute at 80° (178°F) may be considered a …
View paper: Drilling, Completion and Testing of Geothermal Wells CD-1 and CD-2, Caliente, Nevada
Download unavailable
-
Vladimir SOLDO, Leon LEPOSA, Luka BOBAN, Staša BOROVIC
·
World Geothermal Congress
·
2015
·Geothermal Heat Pumps
… a new method, the so called distributed thermal response test (DTRT) has been applied on a 100 m deep borehole heat exchanger (double U pipe) with 152 mm in the outer diameter of borehole. The fundamental difference from the TRT is the measurement of the …
View paper: Implementation of the Distributed Thermal Response Test at Characteristic Geological Regions Throughout the Croatia
PDF: Implementation of the Distributed Thermal Response Test at Characteristic Geological Regions Throughout the Croatia (925 KB)
-
Mikael Philippe, Dominique Marchio, Hervé Lesueur, Alexandre Vrain
·
World Geothermal Congress
·
2010
·29. Geothermal Heat Pumps
… heat exchangers to predicted values using thermal response tests. A scale 1 test facility of horizontal ground heat exchangers has been implemented in BRGM (Orleans - France) to test performance in real conditions. The heat exchanger is divided in four parts …
View paper: An Evaluation of Ground Thermal Properties Measure Accuracy by Thermal Response Test of Horizontal Ground Heat Exchangers
PDF: An Evaluation of Ground Thermal Properties Measure Accuracy by Thermal Response Test of Horizontal Ground Heat Exchangers (4147KB)
-
J. Raymond, G. Robert, R. Therrien, L. Gosselin
·
World Geothermal Congress
·
2010
·29. Geothermal Heat Pumps
… subsurface has been measured with a novel thermal response test using heating cables inserted in a vertical ground heat exchanger. An electric current is applied along the cables to heat the borehole prior to measuring water temperature recovery at various …
View paper: A Novel Thermal Response Test Using Heating Cables
PDF: A Novel Thermal Response Test Using Heating Cables (2537KB)
-
Huajun Wang; Linbo Liu; Chengying Qi
·
Geothermal Resources Council Transactions
·
2010
·Geothermal heat pumps; Downhole heat exchangers; Thermal con
In-situ thermal response tests (TRTs) are widely used to determine the ground thermal conductivity surrounding a borehole heat exchanger (BHE) for geothermal applications. In the present work, three test methods, including the constant heating-flux method …
View paper: Comparisons of Test Methods to Determine the Ground Thermal Conductivity for Geothermal Applications
Download unavailable
-
Geyer, John D.
·
Geothermal Resources Council Transactions
·
2009
·Geothermal heat pumps; Thermal conductivity
… than geologic conditions. Formation Thermal Conductivity Testing (aka: “insitu” testing) is the proven means of measuring soil properties and predicting loop performance at a given site. Mobilization of a drill rig and cost of running a 48-hour thermal …
View paper: In-Situ Thermal Conductivity Testing for Ground-Coupled Heat Exchangers
Download unavailable
-
Vandevier, Joe; Gould, Ben
·
Geothermal Resources Council Transactions
·
2009
·Well pumps
… has been recognized for many years. Electrical submersible pumping (ESP) systems have been used successfully in geothermal and other high temperature applications and show significant promise for future applications. This paper briefly describes the ESP …
View paper: Application of Electrical Submersible Pumping Systems in High Temperature Geothermal Environments
Download unavailable
-
Fujii, Hikari; Okubo, Hiroaki; Itoi, Ryuichi
·
Geothermal Resources Council Transactions
·
2007
·Geothermal heat pumps
A thermal response test (TRT) was conducted in a ground heat exchanger (GHE) of 50m deep drilled in a formation with groundwater flow. During the TRT, the vertical profiles of the formation temperature were monitored using an optical fiber thermometer for …
View paper: Interpretation of Thermal Response Tests in the Presence of Groundwater Flow
Download unavailable
-
Katzenbach, Rolf; Clauss, Frithjof; Waberseck, Thomas; Wagner, Isabel
·
Geothermal Resources Council Transactions
·
2007
·Geothermal heat pumps; Thermal conductivity
… is indispensable. Therefore, the Geothermal Response Test (GRT) is a reliable and effective field investigation procedure. With this contribution the authors present fundamentals of the testing procedure and discuss new enhancements of the Geothermal …
View paper: Geothermal Site Investigation--Present Developments of the Geothermal Response Test
Download unavailable
-
Fujii, Hikari; Okubo, Hiroaki; Itoi, Ryuichi
·
Geothermal Resources Council Transactions
·
2006
·Geothermal Heat Pumps; fiber optical thermometer; Hydrogeolo
Thermal response tests (TRTs) were conducted using optical fiber thermometers in two types of ground heat exchangers (GHEs), coaxial type and U-tube type, drilled in a heterogeneous deposit in Fukuoka City, Japan. For the interpretation of the TRTs, the …
View paper: Thermal Response Tests Using Optical Fiber Thermometers
Download unavailable
-
H. Fujii, D. Ishiyama, J. Rahmatov, F. Inagaki
·
New Zealand Geothermal Workshop
·
2024
·Session 2.3 - DIRECT USE & SOCIAL ENGAGEMENT / COMMUNITY ENG
Ground Source Heat Pumps (GSHP) systems have been widely distributed in several regions of the world due to the low operation costs and environmentally-friendliness. In Central Asian countries, however, the number of installations is very limited due to the …
View paper: Interpretation of the first thermal response test in Central Asian countries
PDF: Interpretation of the first thermal response test in Central Asian countries (967KB)
-
Murat AYDIN, Mustafa ONUR, Altug SISMAN
·
Stanford Geothermal Workshop
·
2017
·Low Temperature
In ground source heat pump (GSHP) applications, determination of thermal properties such as thermal conductivity and diffusivity of ground is essential to make a reliable long term performance predictions of boreholes and system design. Constant heat-flux or …
View paper: A New Method for Constant Temperature Thermal Response Tests
PDF: A New Method for Constant Temperature Thermal Response Tests (2937 KB)
-
Asl, Hadi Farabi; Fujii, Hikari; Kosukegawa, Hiroyuki
·
Geothermal Resources Council Transactions
·
2015
·Heat exchangers; Injection; Geothermal heat pumps
View paper: Heat Exchange Rate Enhancement in Ground Heat Exchangers by Water Injection and Pumping
Download unavailable
-
Murat AYDIN, Altug SISMAN, Ahmet GULTEKIN
·
Stanford Geothermal Workshop
·
2014
·Low Temperature
… especially for long term usage of Ground Source Heat Pump Systems (GSHPS). Therefore long term prediction of heat transfer rate per unit borehole length (unit HTR value) is an important issue to reliably determine the borehole quantity in a project. In …
View paper: Long Term Performance Prediction of a Borehole and Determination of Optimal Thermal Response Test Duration
PDF: Long Term Performance Prediction of a Borehole and Determination of Optimal Thermal Response Test Duration (1278 KB)