Ben BAKER, Daniel PEARL, Mathew STADDON · World Geothermal Congress · 2020 ·Power Generation
… to work together to identify and correct gaps in business processes, equipment and operations that could lead to large-scale industrial accidents. Contact Energy decided to implement a safety lifecycle approach as defined by International Electrotechnical …
View paper: Implementing Safety Lifecycle and Functional Safety with an Existing Organic Rankin Cycle Unit PDF: Implementing Safety Lifecycle and Functional Safety with an Existing Organic Rankin Cycle Unit (941 KB)
R. Winmill · New Zealand Geothermal Workshop · 2020 ·Session 5.1 Drilling
Monitoring and managing well casing integrity is an important part of safely managing geothermal wells over their lifetime. A failure of casing integrity can lead to contamination of shallow aquifers and ultimately could even lead to an uncontrolled blowout. …
View paper: Using Air-Cap Testing to Monitor and Measure Geothermal Well Casing Integrity PDF: Using Air-Cap Testing to Monitor and Measure Geothermal Well Casing Integrity (447KB)
Tom Buchanan, Wade Posten, Sean Berryman · World Geothermal Congress · 2010 ·26. Power Generation
The Steamboat 2 and 3 geothermal power plants owned and Operated by Ormat Nevada, Inc. included four radial flow turbo-expanders originally supplied by a third party vendor with the original plant design. The turbo-expanders have experienced significant …
View paper: Repowering Steamboat 2 and 3 Plants with New Axial Flow Turbines PDF: Repowering Steamboat 2 and 3 Plants with New Axial Flow Turbines (1425KB)
Buchanan, Tom; Posten, Wade; Berryman, Sean · Geothermal Resources Council Transactions · 2009 ·Turbines; Isobutane; Operations management
The Steamboat 2 and 3 geothermal power plants owned and Operated by Ormat Nevada, Inc. included four radial flow turbo-expanders originally supplied by Atlas Copco. The turboexpanders have experienced significant maintenance costs and unscheduled down time …
View paper: Repowering Steamboat 2 and 3 Plants with New Axial Flow Turbines Download unavailable