Skip to content
International Geothermal Association Conference Paper Database Live

Searches title, authors, abstract, keywords and session. Use "quotes" for an exact phrase.

Advanced search

All filled fields must match. Conference and year are added to the filters on the left.

Filters

Show filters
Conference
Year
–

1–12 of 12 papers

  1. Pressure Interference Tests at the Oguni Geothermal Field, Northern Kyushu, Japan

    Sabodh K. Garg and Shigetaka Nakanishi · World Geothermal Congress · 2000 ·Reservoir Evaluation

    … constitute the principal geothermal aquifers. The feedzone pressures indicate that the northwestern Hohi region consists of two pressure zones, i.e., a high-pressure zone in the southern part of the Oguni geothermal field, and a low-pressure zone in the …

    View paper: Pressure Interference Tests at the Oguni Geothermal Field, Northern Kyushu, Japan PDF: Pressure Interference Tests at the Oguni Geothermal Field, Northern Kyushu, Japan (866 B)

  2. Interference Between Constant Rate and Constant Pressure Wells

    Sageev, Abraham; Horne, Roland N. · Geothermal Resources Council Transactions · 1985 ·Well testing; Pressure transient analysis; Interference test

    A pressure transient analysis method is presented for interference between wells producing at constant rate and wells producing at constant pressure. The wells are modeled as two line source wells in an infinite reservoir. The first well produces at a …

    View paper: Interference Between Constant Rate and Constant Pressure Wells Download unavailable

  3. The Application of Kalman Filter to Pressure Interference Test Analysis

    Itoi, Ryuichi; Arakawa, Hiroshi; Fukuda, Michihiro; Jinno, Kenji · Geothermal Resources Council Transactions · 1990 ·Well testing; Interference testing

    … the principle of superposition is employed to express the pressure change at a observation well. This solution is utilized as a measurement equation in the Kalman filtering. Since the measurement equation is nonlinear with respect to the parameters of …

    View paper: The Application of Kalman Filter to Pressure Interference Test Analysis Download unavailable

  4. Pressure Transient Tests at the Okuaizu Geothermal Field in Japan

    Ishido, Tsuneo · Geothermal Resources Council Transactions · 1985 ·Well testing; Pressure transient analysis; Injection testing

    … OA-4 drilled in the Okauizu geothermal field in Japan. The pressure transient data were interpreted using conventional type curve and graphical analysis. The early time data of each test is closely approximated by a line of 1/2 slope of a log-log plot which …

    View paper: Pressure Transient Tests at the Okuaizu Geothermal Field in Japan Download unavailable

  5. A Case History of a Multi-Well Interference Test Program at the Uenotai Geothermal Field, Akita Prefecture, Japan

    Menzies, A. J.; Antunez, E. U.; Sanyal, S. K.; Naka, T.; Takeuchi, R.; Iwata, S.; Saeki, Y.; Inoue, T. · Geothermal Resources Council Transactions · 1990 ·Well testing; Interference testing; Flow testing; Pressure t

    … eight production wells have a combined output of 26.1 MW. Pressure drawdown into wells is as high as 120 ksc and this caused some of the wells to produce superheated steam. The high drawdowns, high injection pressures and relatively low reservoir …

    View paper: A Case History of a Multi-Well Interference Test Program at the Uenotai Geothermal Field, Akita Prefecture, Japan Download unavailable

  6. Interference Testing near a Steam Cap

    Sageev, Abraham · Geothermal Resources Council Transactions · 1985 ·Well testing; Interference testing; Computer modeling; Reser

    … A conventional early time log-log analysis of interference pressure data may yield high values of reservoir parameters each as transmissibility and storability. The presented method uses these high value of reservoir parameters for detecting the presence of …

    View paper: Interference Testing near a Steam Cap Download unavailable

  7. 1981 Interference Well Testing: Beowawe, NV

    Epperson, I. J. · Geothermal Resources Council Transactions · 1983 ·Well testing; Interference testing; Hydrogeology

    … the results of individual well flow tests and indicate pressure communication between all tested wells, even though each well is completed in a different geological interval. All data indicate that the geologically complicate Beowawe system is very …

    View paper: 1981 Interference Well Testing: Beowawe, NV Download unavailable

  8. Interference Testing of the Rhyolites Overlying the Ohaaki Geothermal Reservoir

    McGuinness, Mark J. · Geothermal Resources Council Transactions · 1985 ·Well testing; Interference testing; Fluid dynamics; Geologic

    … geothermal reservoir in New Zealand have been extensively pressure tested. There is clear evidence that there are two areas of rhyolite, a small one directly over the Ohaaki reservoir, and a much larger on outside this region. The two areas are not in good …

    View paper: Interference Testing of the Rhyolites Overlying the Ohaaki Geothermal Reservoir Download unavailable

  9. An Integrated Test Program for the Definition of a High Temperature Geothermal Reservoir: A Case Study from the Zunil Geothermal Field, Guatemala

    Menzies, A. J.; Granados, E. E.; Sanyal, S. K.; Mink, L. L.; Merida-I., L.; Caicedo-A., A. · Geothermal Resources Council Transactions · 1990 ·Well testing; Flow testing; Interference testing

    … to provide the necessary additional capacity. Analysis of pressure buildup and interference tests give a transmissivity of 1,600 to 8,500 md.m, typical for high temperature geothermal fields. The interference test also indicates that the central wells (ZCQ …

    View paper: An Integrated Test Program for the Definition of a High Temperature Geothermal Reservoir: A Case Study from the Zunil Geothermal Field, Guatemala Download unavailable

  10. Dixie Valley Six Well Flow Test

    Desormier, William L. · Geothermal Resources Council Transactions · 1987 ·Well testing; Flow testing; Interference testing; Hydrogeolo

    … rate of 5.9 million pounds/hour. During the test, downhole pressures were monitored in eight surrounding wells. Downhole pressure and temperatures surveys were run in each of the flowing wells, usually in conjunction with productivity tests. Results from the …

    View paper: Dixie Valley Six Well Flow Test Download unavailable

  11. Interaction Between Surface Facilities and Wells at an Operating Geothermal Flash Plant

    Stock, Don D. · Geothermal Resources Council Transactions · 1991 ·Well testing; Flow testing; Fluid dynamics; Power plant desi

    … or a piping modification Such changes alter the operating pressures throughout the system, including wellhead pressures at all the wells. All well outputs will therefore be affected, regardless of their location. As a result, connecting a new 10 MW well to …

    View paper: Interaction Between Surface Facilities and Wells at an Operating Geothermal Flash Plant Download unavailable

  12. Numerical Modeling of the High-Temperature Geothermal System of Amatitlan, Guatemala

    Pham, M.; Menzies, A. J.; Sanyal, S. K.; Lima, E.; Shimada, K.; Juarez, J.; Cuevas, A. · Geothermal Resources Council Transactions · 1996 ·Reservoir modeling; Computer modeling; Well testing; Flow te

    View paper: Numerical Modeling of the High-Temperature Geothermal System of Amatitlan, Guatemala Download unavailable

Papers are freely accessible. Copyright remains with the authors and conference organisers as stated on each paper.

IGA Conference Paper Database · New search