Searches title, authors, abstract, keywords and session. Use "quotes" for an exact phrase.
All filled fields must match. Conference and year are added to the filters on the left.
Rizaldy and S.J. Zarrouk · New Zealand Geothermal Workshop · 2016 ·5.2
… with 5–15% average deviation. The homogenous and Harrison-Freeston methods better suit smaller pipe sizes (10”–18”), with an average deviation of 5–28%. The Lockhart-Martinelli, Zhao-Freeston and Brill-Mukherjee correlations were found to be less …
View paper: Pressure Drop in Large Diameter Geothermal Two-Phase Pipelines PDF: Pressure Drop in Large Diameter Geothermal Two-Phase Pipelines (573KB)