Erik Witter, Hyunjun Oh, Rebecca Barney, Guangdong Zhu, Joshua McTigue
·
World Geothermal Congress
·
2026
… grid and increases grid connection requirements. Cold underground thermal energy storage (Cold-UTES) is one solution for managing data center cooling loads. These systems leverage the natural thermal capacity of the earth by chilling the subsurface during …
View paper: A Techno-Economic Model of a Data Center with Cold Underground Thermal Energy Storage
PDF: A Techno-Economic Model of a Data Center with Cold Underground Thermal Energy Storage
-
Hannes Gernandt, Franziska Krenzlin, Willem Hagemann, and Johannes Schiffer
·
Der Geothermiekongress
·
2023
Underground thermal energy storages (UTES) are essential for decarbonizing the existing heating networks. To accurately simulate the storage and the connected heat supply system, typically detailed numerical models of the UTES and the heat supply system are …
View paper: Data-based modeling for optimizing the operation of seasonal underground storages
PDF: Data-based modeling for optimizing the operation of seasonal underground storages (240 KB)
-
Penfield, Robin; Zehner, Richard; Coolbaugh, Mark; Shevenell, Lisa; Hastings, Jordan; Johnson, Gary; Snyder, Walter; Morgos, Daniella; Kurz, Kim; Sabin, Andrew; Lazaro, Michael; Bjornstad, Steven; Halsey, Greg
·
Geothermal Resources Council Transactions
·
2010
·Exploration; Databases; Geochemical surveys; Geothermometers
… Geothermal Energy have compiled nearly 50,000 Great Basin groundwater samples into an Access database, encompassing all known spatial, physical, and geochemical features. The database schema is a partial template for the National Geothermal Data System …
View paper: Geothermal Site Assessment using the National Geothermal Data System (NGDS), with Examples from the Hawthorne Ammunition Depot Area
Download unavailable
-
Ignasi HERMS, Jordi GARCÃA-CÉSPEDES, ARNÓ, José Juan DE FELIPE
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
… energy consumption and compressor operation time of the ground source heat pump (GSHP). Through the proper selection of the sampling frequency (minute-resolved) and a smart data processing, it was demonstrated the potential of continuous monitoring plus …
View paper: Long-Term Detailed Monitoring and Energy Performance Evaluation of a Ground Source Heat Pump System. A Study Case in Catalonia
PDF: Long-Term Detailed Monitoring and Energy Performance Evaluation of a Ground Source Heat Pump System. A Study Case in Catalonia (1070 KB)
-
Soheil PORKHIAL, Hossein LOTFIZADEH, Mohsen TAGHADOSI, Abbasali ABOUEI MEHRIZI
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
Ground Source Heat Pumps (GSHP) have become as one of the most indispensable cooling and heating systems in residential applications since they have higher energy efficiency compared to the other conventional alternatives all around the world. In this study, …
View paper: Experimental Performance Analysis of Ground Source Heat Pumps (GSHPs) in Taleghan-Iran
PDF: Experimental Performance Analysis of Ground Source Heat Pumps (GSHPs) in Taleghan-Iran (1098 KB)
-
David P. ZURMUHL, Maciej Z. LUKAWSKI, Gloria A. AGUIRRE, George P. SCHNAARS, Koenraad F. BECKERS, C. Lindsay ANDERSON, Jefferson W. TESTER
·
Stanford Geothermal Workshop
·
2018
·Low Temperature
… supplying year-round cooling to representative small data centers with cooling loads less than 500 kWth were analyzed and compared to air-source heat pumps (ASHPs). A numerical model was developed in TRNSYS software to simulate the operation of …
View paper: Hybrid Geothermal Heat Pumps for Cooling Telecommunications Data Centers
PDF: Hybrid Geothermal Heat Pumps for Cooling Telecommunications Data Centers (424 KB)
-
Nicholson, Sarah R.; Antoun, Sylvie; Frith, Sheldon
·
Geothermal Resources Council Transactions
·
2023
·Machine learning; Thermal conductivity
View paper: Comparing UMNY Machine Learning Predictions of Ground Temperature and Soil Thermal Conductivity to Real-World Sensor Measurements from Across the World
Download unavailable
-
Antonio GALGARO, Giorgia DALLA SANTA, Jacques VERCRUYSSE, Dimitrios MENDRINOS, Fabio MOIA, Angelo ZARRELLA
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
… of a GSHP system depends on the thermal performance of the ground heat exchangers which, in turn, depends primarily on the local ground heat exchange capacity, which represents a sort of fixed factor in the designing of new GSHP systems, due to its …
View paper: A First European Collection of Thermal Response Tests
PDF: A First European Collection of Thermal Response Tests (805 KB)
-
Yoshitaka SAKATA, Takao KATSURA and Katsunori NAGANO
·
World Geothermal Congress
·
2020
·Geothermal Heat Pumps
Required lengths of borehole heat exchanger for a ground-source heat pump system is dependent on various factors regarding to building, heat pump, geology and other facilities. Especially in Japan, geology and climate conditions are variable among each site …
View paper: Regional Evaluation and Statistical Modeling of Required Lengths for a Borehole Heat Exchanger Considering Varied Geology in Japan
PDF: Regional Evaluation and Statistical Modeling of Required Lengths for a Borehole Heat Exchanger Considering Varied Geology in Japan (1570 KB)
-
Youhei UCHIDA, Mayumi YOSHIOKA, Gaurav SHRESTHA, Yasumori TAKAHASHI
·
World Geothermal Congress
·
2015
·Hydrogeology
Ground-Source Heat Pump System (GSHP System) has been increasing in Europe and the United States when the oil shocks of the 1970’s occurred. Initial cost of the GSHP System in Japan, however, is higher than that of air-source heat pump system, therefore, such …
View paper: Study on Shallow Geothermal and Hydrogeology at Fukushima Renewable Energy Institute, AIST
PDF: Study on Shallow Geothermal and Hydrogeology at Fukushima Renewable Energy Institute, AIST (1364 KB)
-
Ditlefsen, Vangkilde-Pedersen, Sørensen, Bjørn, Højberg, Møller
·
European Geothermal Conference
·
2013
·11 Geothermal Markets -Shallow (SG6)
… to e.g. Sweden and Germany. Today, the total number of ground source heat pumps in Denmark is around 27,000, currently increasing by 5,000 per year. By far, most of the existing installations are horizontal closed loop systems, while four to five hundred …
View paper: GeoEnergy – a national shallow geothermal research project
PDF: GeoEnergy – a national shallow geothermal research project (378 KB)