Searches title, authors, abstract, keywords and session. Use "quotes" for an exact phrase.
All filled fields must match. Conference and year are added to the filters on the left.
Perfecto G. LIM and Irvin A. MORTILLERO · World Geothermal Congress · 2015 ·Corrosion and Scaling
… for continuous, unattended monitoring. The Ion-Selective Electrode method is a simple analytical technique for directly analyzing small concentrations of cation species like sodium (Na+) in a solution. The ROSS Sodium electrode is used as the indicator …
View paper: Steam Purity Monitoring of Low Sodium by Ion Selective Electrode Method PDF: Steam Purity Monitoring of Low Sodium by Ion Selective Electrode Method (612 KB)
Henfling, Joe; von Hirtz, Paul; Broaddus, Mark; Kunzman, Russ; Wright, Andrew; Hess, Ryan; Cashion, Zack · Geothermal Resources Council Transactions · 2022 ·Equipment design; Well logging; High temperature reservoirs
View paper: Development of a High Temperature, High Pressure Logging Tool for Downhole pH Measurements Download unavailable
Montgomery, Jerry; Bowers, Roger L.; Kofoed, Val · Geothermal Resources Council Transactions · 2005 ·Geophysical surveys; Mapping; Hydrogeology; Exploration
View paper: Characterization of Geothermal Resources using New Geophysical Technology Download unavailable
Shore, Greg A. · Geothermal Resources Council Transactions · 1983 ·Exploration; Geophysical surveys; Resistivity surveys
In the Mt. Cayley area of southwestern British Columbia, the multiple pole-pole resistivity method has yielded data in terrain conditions which precluded continued use of conventional survey arrays. An anomaly of potential geothermal significance has been …
View paper: Application and Interpretation of Multiple Pole-Pole Resistivity Survey, Mt. Cayley, B.C. Download unavailable