-
Cath, Tzahi Y.; Walker, Nathan; Childress, Amy E.; Hutton, Mirinda; Weinberg, Assaf
·
Geothermal Resources Council Transactions
·
2008
·Cooling Towers
Cooling towers in geothermal power plants use large quantities of water to ensure high-efficiency generation of power. However, low quality of make up water results in inefficient use of water and discharge of large volumes of blowdown water. Membrane …
View paper: Assessment of Traditional and Novel Membrane Processes for Recovery of Cooling Tower Water in Geothermal Power Plants
Download unavailable
-
Bedell, Stephen A.
·
Geothermal Resources Council Transactions
·
2004
·Power Plants; Condensate; Cooling Towers; Hydrogen sulfide
View paper: Hydrogen Sulfide Abatement Chemistry in Geothermal Plant Cooling Towers
Download unavailable
-
Mortensen, Kenneth P.
·
Geothermal Resources Council Transactions
·
1996
·Cooling towers; Brine chemistry; Corrosion; Fouling
View paper: State of the Art Cooling Tower Technology in Geothermal Power Applications
Download unavailable
-
Clevinger, R. Brian
·
Geothermal Resources Council Transactions
·
1992
·Brine chemistry; Ammonia; Cooling towers; Nitrites; Fouling
View paper: Nitrogen Chemistry in Cooling Tower Water at Magma Power Company's Four Salton Sea KGRA Power Plants
Download unavailable
-
Rahmatul A. Andini, Zakaria Z. Sumantoro, Munggang H. Purnanto
·
World Geothermal Congress
·
2026
·Power Plant Operations & Maintenance
Cooling towers (CTs) play a vital role in the condensation process of the cooling water cycle in a geothermal power plant. They cool down the water used in the condenser, allowing it to maintain an optimal condensation rate. In geothermal power plants with …
View paper: Integrated Mechanical and Chemical Treatment for Maintaining Cooling Tower Performance: A Case study from Muara Laboh Geothermal Field
PDF: Integrated Mechanical and Chemical Treatment for Maintaining Cooling Tower Performance: A Case study from Muara Laboh Geothermal Field
-
Fikrul Jihad
·
World Geothermal Congress
·
2026
·Poster
… application of an artificial neural network to predict the cooling tower’s performance at Lahendong Unit 5&6 Geothermal Power Plant. The cooling tower is one of the many critical equipment of a GPP. Its purpose is to cool hot water that exits the condenser. …
View paper: Application of Artificial Neural Network to Predict Cooling Tower’s Performance at Lahendong Unit 5&6 Geothermal Power Plant
PDF: Application of Artificial Neural Network to Predict Cooling Tower’s Performance at Lahendong Unit 5&6 Geothermal Power Plant (855KB)
-
A.S. Nugraha, A. Yani, P. Budiman, T.P. Nainggolan, P. Valdirmarsson
·
New Zealand Geothermal Workshop
·
2023
·Session 7.2 - PRODUCTION & MANAGEMENT 2
… with pressure 1.32 bara is connected to the existing wet cooling tower as the cooling system. The calculation using Scilab and CoolProp as numerical computation, with vaporizer pressure 8.63 bara or 7.70 barg resulting net power 1795.32 kW and SSI value …
View paper: Study & design of binary ORC using wet cooling tower (existing) of unit V & VI in Lahendong geothermal field, Indonesia
PDF: Study & design of binary ORC using wet cooling tower (existing) of unit V & VI in Lahendong geothermal field, Indonesia (1200KB)
-
M. Young, S.J. Zarrouk
·
New Zealand Geothermal Workshop
·
2022
·Session 3.3 - PRODUCTION & MANAGEMENT 2
The chemical dosing for Te Mihi geothermal power station cooling tower water had previously been investigated and optimised. This involved continuous dosing of 30% caustic soda for pH control of the cooling water, with periodic shock doses of a quaternary …
View paper: Chemical Dosing for Te Mihi Geothermal Station Cooling Towers: Update
PDF: Chemical Dosing for Te Mihi Geothermal Station Cooling Towers: Update (535KB)
-
M. Young and S.J. Zarrouk
·
New Zealand Geothermal Workshop
·
2021
·Seesion 4.2 - Production and Management 2
… power station in New Zealand with a natural draft cooling tower. The concrete construction of the cooling tower influenced the locations vulnerable to attack from condensate/cooling water pH and from microorganism growth, and this altered the way …
View paper: INVESTIGATION OF COOLING WATER CHEMICAL DOSING: THE OHAAKI GEOTHERMAL POWER STATION COOLING TOWER
PDF: INVESTIGATION OF COOLING WATER CHEMICAL DOSING: THE OHAAKI GEOTHERMAL POWER STATION COOLING TOWER (1087KB)
-
T. Clark, K. Wade, N. Gibson
·
New Zealand Geothermal Workshop
·
2020
·Session 5.2 Above Ground Technology 3
Evaporative cooling water systems in geothermal power plants can pose several challenges for geothermal operators. The challenges of corrosion, deposition and biological control can be magnified in systems utilising direct contact condensers, due to the …
View paper: Microbially Induced Degradation of Fibre Reinforced Plastic (FRP) in the Cooling Tower of a Geothermal Power Station
PDF: Microbially Induced Degradation of Fibre Reinforced Plastic (FRP) in the Cooling Tower of a Geothermal Power Station (481KB)
-
Alessio BARDI, Sara MONTOMOLI, Marco PACI, Alessandro LENZI, Luca BERTOCCHI, Andrea GARAGIOLA, Alessandro SANTINI, Lorena FREIRE
·
World Geothermal Congress
·
2020
·Power Generation
A cooling tower in a direct steam geothermal power unit behaves like a direct-contact heat exchanger, where geothermal condensed steam exchanges heat into the air. Heat is transferred by radiation from the surface of the droplets, by conduction and convection …
View paper: Hybrid Cooling Tower Retrofit in a Geothermal Power Plant: Outcomes from H2020 Matching Project
PDF: Hybrid Cooling Tower Retrofit in a Geothermal Power Plant: Outcomes from H2020 Matching Project (2835 KB)
-
Ernesto Q. MALICAD, Jr., Virgilio G. LAPUZ, Jr., Martin Jude V. LACAMBRA
·
World Geothermal Congress
·
2020
·Case Histories
… damage to its power plant facilities particularly the cooling towers. Cooling towers are an essential integral part of the geothermal power plants the damage of which can result to extended shut down of operations. This prompted EDC to enhance and …
View paper: Comparison of Wind Pressures Using Wind Tunnel Test (WTT), the Prescriptive Approach (NSCP 2015), and Computational Fluid Dynamics (CFD) in the Case of Cooling Towers for Geothermal Power Plants
PDF: Comparison of Wind Pressures Using Wind Tunnel Test (WTT), the Prescriptive Approach (NSCP 2015), and Computational Fluid Dynamics (CFD) in the Case of Cooling Towers for Geothermal Power Plants (1515 KB)
-
Supriadinata MARZA, Murdoko Broto KUSUMO, Fajar Dhani WARDHANA; Rita Nur ANGGRAENI
·
World Geothermal Congress
·
2020
·Power Generation
… It will undergo an oxidation reaction with the air in the cooling tower forming a solid sulfur compound. Impurities other than sulfur mineral deposits are microbiological deposits in the form of algae, moss and slime which are formed due to the cooling …
View paper: Handling of Micro-Organisms Growth and Sulfur Deposit in the Cooling Tower of Patuha Geothermal Power Plant (A Lesson Learned from Patuha Geothermal Power Plant, Indonesia)
PDF: Handling of Micro-Organisms Growth and Sulfur Deposit in the Cooling Tower of Patuha Geothermal Power Plant (A Lesson Learned from Patuha Geothermal Power Plant, Indonesia) (869 KB)
-
Amri ZEIN
·
World Geothermal Congress
·
2020
·Power Generation
Unit 1 Cooling Tower (CT) in Wayang Windu Geothermal Power Plant has been operating since 2000. There were excellent works had been conducted by Star Energy Geothermal (Wayang Windu) team in order to improve the CT performance while assuring the excellent CT …
View paper: Modification of Wayang Windu Unit 1 Cooling Tower to Improve the CT Performance
PDF: Modification of Wayang Windu Unit 1 Cooling Tower to Improve the CT Performance (1444 KB)
-
A. Zein, M. Kuntoaji
·
New Zealand Geothermal Workshop
·
2019
·Session 4.1 – Drilling and above ground technology 1
Unit 1 Cooling Tower (CT) in Wayang Windu Geothermal Power Plant has been operating since 2000. Extensive works have been conducted by Star Energy Geothermal (Wayang Windu) team in order to improve the performance of the CT while assuring excellent …
View paper: MODIFICATION OF UNIT 1 COOLING TOWER (CT) TO IMPROVE THE CT PERFORMANCE IN STAR ENERGY GEOTHERMAL (WAYANG WINDU) LTD
PDF: MODIFICATION OF UNIT 1 COOLING TOWER (CT) TO IMPROVE THE CT PERFORMANCE IN STAR ENERGY GEOTHERMAL (WAYANG WINDU) LTD (698KB)
-
Gloria Andrea AGUIRRE, Koenraad F. BECKERS, Maciej Z. LUKAWSKI, and Jefferson W. TESTER
·
Stanford Geothermal Workshop
·
2017
·Low Temperature
… around 8 kWth of heat. The annual electricity bill for cooling these shelters with conventional air-source heat pump (ASHP) systems and their corresponding carbon footprint are significant. This paper presents methodology and results of techno-economic …
View paper: Hybrid Ground-Source Heat Pumps for Cooling Cellular Tower Shelters: from Campus Living Laboratory to Nationwide Deployment
PDF: Hybrid Ground-Source Heat Pumps for Cooling Cellular Tower Shelters: from Campus Living Laboratory to Nationwide Deployment (1194 KB)
-
D. Morrison
·
New Zealand Geothermal Workshop
·
2017
·Session 5.1: Production
… subsequent implementation of mitigations to the Te Mihi cooling towers to modify a narrow band tonal component of far-field noise. Assessing the actual noise emissions from Te Mihi proved to be particularly challenging because the actual measured …
View paper: TE MIHI GEOTHERMAL POWER STATION – FAR-FIELD NOISE MITIGATION TO THE TE MIHI COOLING TOWERS
PDF: TE MIHI GEOTHERMAL POWER STATION – FAR-FIELD NOISE MITIGATION TO THE TE MIHI COOLING TOWERS (834KB)
-
Marco FAVILLA, Flavio DIFRANCESCO
·
World Geothermal Congress
·
2015
·Power Generation
… motor with vertical shaft for direct driving of geothermal cooling towers. This application requires a high load torque at low rpm and the brushless motor is the only AC motor that provides this load characteristic. The project requires a careful choice of …
View paper: Brushless Motors for Geothermal Cooling Towers
PDF: Brushless Motors for Geothermal Cooling Towers (517 KB)
-
Amri ZEIN, Djamaludin KURNIADI
·
World Geothermal Congress
·
2015
·Power Generation
Unit 1 Cooling Tower (CT) fan stack was designed with height of 6 feet and had relatively straight vertical panels which didn’t produce significant velocity recovery. In other hand, due to Wayang Windu Geothermal Plant is located in the mountain; the CT is …
View paper: Unit 1 Cooling Tower Fan Stack Replacement to Improve Cooling Tower Perfomance
PDF: Unit 1 Cooling Tower Fan Stack Replacement to Improve Cooling Tower Perfomance (1589 KB)
-
Hillard, Catherine; Benn, Brian
·
Geothermal Resources Council Transactions
·
2014
·Power plant design and operation; Effluent abatement; Air qu
H2S abatement efficiency in geothermal crossflow cooling towers can be improved by increasing the reaction time and dissolved oxygen concentration in the circulating water (Ballantine, 1993). Additional efficiency is accomplished at Geysers? units with …
View paper: Improvements in Residence Time and Air Oxidation For H2S Abatement in The Geysers' Geothermal Power Plants With Direct-Contact Condensers and Crossflow Cooling Towers
Download unavailable
-
Amri Zein, Paul A. Taylor, Heribertus Dwiyudha
·
World Geothermal Congress
·
2010
·26. Power Generation
The cooling water (CW) design flow to the condenser of Unit 1, 110MWe Wayang Windu Geothermal Power Plant, West Java, as per heat balance is 4639 kg/s. Although this flow was achieved during first commissioning, it reduced quickly in normal operation which …
View paper: Modification of Condenser Nozzle and Cooling Tower Exit Screen to Increase Condenser Performance
PDF: Modification of Condenser Nozzle and Cooling Tower Exit Screen to Increase Condenser Performance (1385KB)
-
Karim Bourouni, Mohamed Thameur Chaibi, Mohamed Mehdi Bassem
·
World Geothermal Congress
·
2010
·34. District Heating and Agriculture
… crops to damage by high temperatures has driven the use of cooling towers for dropping temperature to an appropriate level for crop irrigation. Cross flow mechanical cooling towers widely spreads all over the south region of the country. These towers are …
View paper: Experimental Investigation of Cross-Flow Geothermal Water Cooling Tower Used for Agriculture Purposes in the South Tunisia
PDF: Experimental Investigation of Cross-Flow Geothermal Water Cooling Tower Used for Agriculture Purposes in the South Tunisia (157KB)
-
Hal Gurgenci and Zhiqiang Guan
·
Australian Geothermal Energy Conference
·
2010
Design of efficient natural draft dry cooling system is essential for Australian geothermal power plant applications. In fact, dry cooling may be the only option for most geothermal power plants planned to be established in Australia since these areas have …
View paper: New Design Concepts for Natural Draft Dry Cooling Towers
PDF: New Design Concepts for Natural Draft Dry Cooling Towers (129KB)
-
Lew Bacon, Joe Jordan and Warren Pearson
·
World Geothermal Congress
·
1995
·SECTION 11 - Corrosion and Scaling
cooling water systems provide the proliferation of organisms reducing operating increasing plant maintenance systcms tu fouling and Induced Corrosion (MIC) due to presence of scveral groups of which obtain their energy the oxidation of gases in geothermal …
View paper: Microbiology and Corrosion in Geothermal Natural Draft Cooling Towers
PDF: Microbiology and Corrosion in Geothermal Natural Draft Cooling Towers
-
Morrison, Robert D.
·
Geothermal Resources Council Transactions
·
1978
·Power plant design and operation; Cooling towers; Waste mana
… process requires a substantial quantity of water for the cooling of the secondary or working fluid. Once this cooling water has left the condenser in such a system, it requires some form of process to lower its temperature. Several process alternatives are …
View paper: Utilization of Geothermal Cooling Waters for Waste Containment
Download unavailable