-
E. Yanto, A. Budiyanto, A. Tiofami, F.E. Marastio, D. Khasani, P. Budiman, H. Suranto
·
New Zealand Geothermal Workshop
·
2023
·Session 2.2 - PRODUCTION & MANAGEMENT 1
In Lumut Balai geothermal projects, where suitable reinjection wells are lacking, the temporary reinjection of hot fluid into high-temperature wells has become necessary, albeit risky. Initially designated as production wells, three wells have been …
View paper: Analysis of heat recovery time predictions for multiple periods of temporary reinjection in geothermal well production at Lumut Balai field
PDF: Analysis of heat recovery time predictions for multiple periods of temporary reinjection in geothermal well production at Lumut Balai field (645KB)
-
Erwandi YANTO, Asep Mamat Rohmat SOLIHAT, Miran AFRIANA, Dzuriat KHASANI, Priatna BUDIMAN, Hadi SURANTO
·
Stanford Geothermal Workshop
·
2023
·Field Studies
Non-Condensable Gas (NCG) is a natural component of geothermal fluids that it’s not easy to condense by condensing process at the condenser. It has the ability to interfere with the heat transfer proses in the condenser by raising the temperature with the …
View paper: Added Value of Optimizing Single Liquid Ring Vacuum Pump (LRVP) in Lumut Balai Geothermal Power Plant
PDF: Added Value of Optimizing Single Liquid Ring Vacuum Pump (LRVP) in Lumut Balai Geothermal Power Plant (925 KB)
-
S.H. Silitonga, E. Yanto, D. Khasani and P. Budiman
·
New Zealand Geothermal Workshop
·
2021
·Session 5.4 - Production and Management 3
Lumut Balai Geothermal Power Plant is a single flash plant which take high-pressure hot water from the reservoir into the lowpressure tank then using the resulting steam to turn the turbine. After turning the steam turbine condensed using a direct contact …
View paper: GENERATOR, TURBINE AND THERMAL EFFICIENCY OF LUMUT BALAI GEOTHERMAL POWER PLANT
PDF: GENERATOR, TURBINE AND THERMAL EFFICIENCY OF LUMUT BALAI GEOTHERMAL POWER PLANT (382KB)
-
Erwandi YANTO, Muhammad Abimas HALIMZIKRI, Aris BUDIYANTO, Andre TIOFAMI, Dzuriat KHASANI, Hadi SURANTO
·
Stanford Geothermal Workshop
·
2021
·General
Cooling tower (CT) water treatment is very important to minimize the growth of microorganisms, minimize the formation of scaling, minimize corrosion and minimize sediment or solids deposition on the contact area of ​​heat transfer on the surface. The …
View paper: The Importance of Cooling Water Treatment System at Lumut Balai Geothermal Power Plant
PDF: The Importance of Cooling Water Treatment System at Lumut Balai Geothermal Power Plant (1265 KB)
-
Yose A. FARASI, SIHANA, KHASANI, Deny KURNIAWAN
·
World Geothermal Congress
·
2020
·Power Generation
Jailolo geothermal field located in Western Halmahera will be develop as geothermal power plant to meet the electricity demand in Northern Maluku. The geothermal fluid is estimated to have the characteristics of two-phase medium temperature-water dominated …
View paper: Thermodynamics Analysis of Kalina Cycle System (KCS) 11 for Jailolo Geothermal Field - Halmahera, Indonesia
PDF: Thermodynamics Analysis of Kalina Cycle System (KCS) 11 for Jailolo Geothermal Field - Halmahera, Indonesia (537 KB)
-
Hari Agung Yuniarto, Ruly Husnie Ridwan, Khasani, Imam Bhaskara
·
Indonesian Geothermal Association Conference
·
2017
In pursuance of increasing power plants’ competitiveness in energy market, these power plants need to embrace a proper operating and maintenance methodology in order to lessen the level of O & M (operation and maintenance) costs. Similar to this, Geothermal …
View paper: A Concept of Reliability Centred Maintenance Applied to Geothermal Power Plant
PDF: A Concept of Reliability Centred Maintenance Applied to Geothermal Power Plant (323KB)
-
KHASANI, Ryuichi ITOI and Sadiq J. ZARROUK
·
World Geothermal Congress
·
2015
·Reservoir Engineering
The continuous measurement of mass flow rates during output testing from a geothermal production well 2H-21 of Hatchobaru geothermal field, Japan are relatively short. Field data from a horizontal discharge into a twin separator was used to evaluate and …
View paper: The Utilization of Transient Output Measurement to Characterize Geothermal Reservoir Properties Using AWTAS for Well 2H-21 at Hatchobaru Geothermal Field, Japan
PDF: The Utilization of Transient Output Measurement to Characterize Geothermal Reservoir Properties Using AWTAS for Well 2H-21 at Hatchobaru Geothermal Field, Japan (631 KB)
-
Nugroho Agung PAMBUDI, Ryuichi ITOI, Saeid JALILINASRABADY, Puji SIRAIT and Khasani JAELANI
·
World Geothermal Congress
·
2015
·Power Generation
Performance improvement in existing single-flash geothermal power plant by applying three cases of expansion design, including double-flash, single-flash combined with the binary, double-flash combined with the binary have been carried out using the …
View paper: Performance Improvement of Single-Flash Geothermal Power Plant Applying Three Cases Development Scenarios Using Thermodynamic Methods
PDF: Performance Improvement of Single-Flash Geothermal Power Plant Applying Three Cases Development Scenarios Using Thermodynamic Methods (1357 KB)
-
Himawan T.B.M. PETRUS, Pri UTAMI, I Wayan WARMADA, Khasani Moh JAELANI, Kusmono KUSMONO, Indra PERDANA
·
World Geothermal Congress
·
2015
·Sustainability
As well as being environmentally friendly, renewable, and sustainable, geothermal energy is indigenous meaning that it can ensure energy supply to the surrounding community. Most of geothermal potential in the eastern part of Indonesia has not been utilized, …
View paper: Geothermal Energy for Green, Sustainable Development and Community Prosperity in the Eastern Indonesia: NZAID-Gadjah Mada University-supported CaRED Program
PDF: Geothermal Energy for Green, Sustainable Development and Community Prosperity in the Eastern Indonesia: NZAID-Gadjah Mada University-supported CaRED Program (405 KB)
-
Khasani, Sugiyono, Joko WALUYO, Fauzun and Ruly Husnie RIDWAN
·
Indonesian Geothermal Association Conference
·
2014
The migration from hot brine injection system to cold brine injection system in managing liquid disposal at Dieng geothermal field was adopted to minimize the operational problems due to the presence of solid deposition. However, this attempt seemed not to be …
View paper: Hydraulic Analysis of Brine Reinjection Pump Systems at Dieng Geothermal Field, Central Java
PDF: Hydraulic Analysis of Brine Reinjection Pump Systems at Dieng Geothermal Field, Central Java (368 KB)
-
Hin, Takeshio; Itoi, Ryuichi; Tanaka, Toshiaki; Pambudi, N. Agung; Khasani
·
Geothermal Resources Council Transactions
·
2013
·Reservoir modeling; Lithology; Permeability
A three dimensional numerical reservoir model of the Dieng geothermal field was developed for the pre-exploitation stage using the TOUGH2 simulator with a forward analysis method. The model was verified by matching temperature profiles of exploration wells. …
View paper: Natural State Modeling of Geothermal Reservoir at Dieng, Central Java, Indonesia
Download unavailable
-
Khasani and Ryuichi ITOI
·
Indonesian Geothermal Association Conference
·
2013
In this study, the deliverability curves of several wells from two geothermal fields, namely geothermal field X and Y are evaluated. From those deliverability curves, it can be analyzed the various problems encountered in the sub-surface wellbore and/or …
View paper: Analysis of Deliverability Curve for Evaluating Potential Problems in the Subsurface of Geothermal Field
PDF: Analysis of Deliverability Curve for Evaluating Potential Problems in the Subsurface of Geothermal Field (323 KB)
-
Nugroho Agung PAMBUDI, Ryuichi ITOI, Saeid JALILINASRABADY, KHASANI
·
Stanford Geothermal Workshop
·
2013
·General
A Single-flash system has been adopted for power generation in the Dieng geothermal power plant, Indonesia, which produces 22 MW of electricity despite of its installed capacity of 60 MW. To achieve optimum energy utilization, a modification of the plant to …
View paper: Performance Evaluation of Double-flash Geothermal Power Plant at Dieng Using Second Law of Thermodynamics
PDF: Performance Evaluation of Double-flash Geothermal Power Plant at Dieng Using Second Law of Thermodynamics (1062 K)
-
Pri Utami, J Khasani, N Roeroe, Z Tuerah, I Bachrun, K Rozaq, and M Gumalag
·
New Zealand Geothermal Workshop
·
2011
·Future Developments
The Lahendong geothermal field is located in Tomohon City, about 30 km south of Manado, the capital city of North Sulawesi Province. The field is located in a beautiful, steep volcanic terrain at about 750 m above sea level, with vigorous thermal …
View paper: Lahendong Geothermal Education Park: a Proposed Geothermal Public Education Facility in the Eastern Part of Indonesia
PDF: Lahendong Geothermal Education Park: a Proposed Geothermal Public Education Facility in the Eastern Part of Indonesia (1 MB)
-
Khasani, Indarto, A. Harijoko, T. Dwikorianto, and S. Patangke
·
Stanford Geothermal Workshop
·
2010
·Production Engineering
The measurement method of steam and water flow rates by using several single frequency waves has been carried out. The measurement apparatus consists of transmitter, receiver, mixer, sound card, and laptop. The transmitter is clamped on the pipe and used for …
View paper: Development of Measurement Method of Steam-Water Two-Phase Flow System Using Single Frequency Waves
PDF: Development of Measurement Method of Steam-Water Two-Phase Flow System Using Single Frequency Waves (345KB)
-
Khasani
·
World Geothermal Congress
·
2010
·22. Reservoir Engineering
The study aims at the possible application of continuous measured wellhead pressure and transient wellbore simulator for evaluating reservoir properties. The first step of the programs is to conduct the continuous measurement of fluid flow and pressure at the …
View paper: Utilization of Continuous Measured Wellhead Pressure for Evaluating Reservoir Properties
PDF: Utilization of Continuous Measured Wellhead Pressure for Evaluating Reservoir Properties (733KB)
-
R. H. Ridwan, P. Pakpahan, T.A. Fauzi, Khasani, A. M. Zulkarnaen, H. Effendi, A. Nasution
·
World Geothermal Congress
·
2010
·26. Power Generation
The parasitic load in each power generation plant is always predominated by the parasitic load from Main Cooling Water System (MCWS). In conventional power generation (e.g. coal fired, gas, and combined cycle power plants), sea-water is usually applied as the …
View paper: Automatic Main Cooling Water System (aMCWS)
PDF: Automatic Main Cooling Water System (aMCWS) (312KB)
-
Khasani, Toshiaki Tanaka, Ryuichi Itoi
·
New Zealand Geothermal Workshop
·
2008
·Reservoir Engineering
The continuous measurement of steam and water flow rates at a production Well 2H-21, at Hatchobaru geothermal field, Japan with a newly developed measurement system to evaluate and understand unsteady state behaviors of well characteristics is carried out. …
View paper: Interpretation of Continuous Measurement of Steam and Water Flow Rates at a Production Well 2H-21, Hatchobaru Geothermal Field, Japan
PDF: Interpretation of Continuous Measurement of Steam and Water Flow Rates at a Production Well 2H-21, Hatchobaru Geothermal Field, Japan (121KB)
-
Khasani, Suhanan, Deendarlianto, A. Harijoko, T. Dwikorianto, and I.B. Prasojo
·
Stanford Geothermal Workshop
·
2008
·Reservoir Engineering
The transient wellbore simulator has been applied to evaluate the deliverability curve on a hypothetical Well-X. The aim of the study is to propose a new procedure in producing a deliverability curve of production well. The procedure of obtaining …
View paper: Application of Transient Wellbore Simulator to Evaluate Deliverability Curve on Hypothetical Well-X
PDF: Application of Transient Wellbore Simulator to Evaluate Deliverability Curve on Hypothetical Well-X (97KB)
-
Khasani, Ryuichi Itoi and Hikari Fujii
·
World Geothermal Congress
·
2005
·11. Reservoir Engineering
Deliverability of geothermal production well is evaluated by measuring wellhead pressure versus mass flow rate at several wellhead pressures. Controlling a main valve of the well results in the changes in wellhead pressure and mass flow rate. However, …
View paper: Numerical Analysis of Transient Behaviours of Geothermal Well Deliverability
PDF: Numerical Analysis of Transient Behaviours of Geothermal Well Deliverability (142KB)
-
Khasani, R. Itoi, T. Tanaka, & M. Fukuda
·
New Zealand Geothermal Workshop
·
2002
·Reservoir Engineering, Modeling and Field Management
This study investigated pressure drops in wellbore under low flow rate conditions and shows them on a deliverability curve. A simple model of a vertical wellbore of uniform diameter, coupled with a reservoir of uniform, radial, horizontal thickness was …
View paper: An Analysis of Pressure Drops in Wellbore, Under Low Flow Rate Conditions, Shown on a Deliverability Curve
PDF: An Analysis of Pressure Drops in Wellbore, Under Low Flow Rate Conditions, Shown on a Deliverability Curve (2021KB)
-
Michihiro Fukuda, Akira Higaki, Khasani, Toshiaki Tanaka and Ryuichi ltoi
·
PNOC-EDC Geothermal Conference
·
2002
·Reservoir Engineering/ Geophysics/ Geology/ Power Plant
In order to investigate the behavior of the reservoir during production and the effects of reinjectim of separated water on production wells in the Otake geothermal area, changes with time in fluid conditions at the wellbottom and feed point in the reservoir …
View paper: Prediction Changes in Well Bottom Fluid Conditions from Well Head Measurements
PDF: Prediction Changes in Well Bottom Fluid Conditions from Well Head Measurements (450KB)