Skip to content
International Geothermal Association Conference Paper Database Live

Searches title, authors, abstract, keywords and session. Use "quotes" for an exact phrase.

Advanced search

All filled fields must match. Conference and year are added to the filters on the left.

Filters

Clear all
Show filters
Conference
Year
–

1–7 of 7 papers

  • Author: Cahyono ×
  1. First Time in Indonesia, CTU Clean Out Totally Plugged Scale : Risks, Mitigations, and Lessons Learned

    Putra, Redha Bhawika; Souvanir, Tommy; Panggabean, Paulus; Purba, Edyson; Arstianti, Haleyna; Cahyono, Agus · Geothermal Resources Council Transactions · 2018 ·Power plant design and operation; Scaling; Well logging

    View paper: First Time in Indonesia, CTU Clean Out Totally Plugged Scale : Risks, Mitigations, and Lessons Learned Download unavailable

  2. OLD LESSONS APPLIED TO MODERN SEPARATOR STATION DESIGN

    B.R. White, E.A. Bramantyo and Y.D. Cahyono · New Zealand Geothermal Workshop · 2018 ·Session 1.2 Geothermal Engineering - Production and Manageme

    Wairakei development was enabled by the development of effective two-phase separators and valuable early research on two-phase flow. The basic separator technology continues in use to the present day, in many cases upscaled, with centralised separator …

    View paper: OLD LESSONS APPLIED TO MODERN SEPARATOR STATION DESIGN PDF: OLD LESSONS APPLIED TO MODERN SEPARATOR STATION DESIGN (970KB)

  3. Conditioning Orifice Application for Steam Flow Measurement at Lahendong Geothermal Field

    Yanuaris Dwi CAHYONO, Fajar Adi PRASETYO, Salvius PATANGKE, P.H. Hendrick SIREGAR · World Geothermal Congress · 2015 ·Production Engineering, Steam Gathering Systems

    Flow measurement is vital for both production and reservoir requirement. Orifice has extensively been used for flow measurement device, due to its cheapness, simplicity and the accuracy. Typical standard orifice require certain long distances between orifice …

    View paper: Conditioning Orifice Application for Steam Flow Measurement at Lahendong Geothermal Field PDF: Conditioning Orifice Application for Steam Flow Measurement at Lahendong Geothermal Field (939 KB)

  4. The Statistical Analysys Comparison Between Lip Pressure and Separator in Production Well Testing at Lahendong and Ulubelu Field

    Mohamad Husni MUBAROK, Yanuaris Dwi CAHYONO, Salvius PATANGKE, Eben Ezer SIAHAAN · World Geothermal Congress · 2015 ·Production Engineering, Steam Gathering Systems

    In order to determine the potential of electrical energy a geothermal well drilled that have been completed, there should be a series of production tests to determine precisely and accurately the characteristics of the geothermal production wells in terms of …

    View paper: The Statistical Analysys Comparison Between Lip Pressure and Separator in Production Well Testing at Lahendong and Ulubelu Field PDF: The Statistical Analysys Comparison Between Lip Pressure and Separator in Production Well Testing at Lahendong and Ulubelu Field (715 KB)

  5. The Application of “Modified Hiriart” for Fluids Flow Measurement in Geothermal Wells Flow Test Using Horizontal Lip Pressure Method

    Yanuaris Dwi Cahyono · Indonesian Geothermal Association Conference · 2013

    In order to know the capacity and fluid properties of a newly drilled geothermal well, it is very critical to carry out a series of flow test measurements. Currently, there are several methods used, but only two of them are used commonly those are Lip …

    View paper: The Application of “Modified Hiriart” for Fluids Flow Measurement in Geothermal Wells Flow Test Using Horizontal Lip Pressure Method PDF: The Application of “Modified Hiriart” for Fluids Flow Measurement in Geothermal Wells Flow Test Using Horizontal Lip Pressure Method (286 KB)

  6. The Utilization of Brine and Condensate Waste for Small Unit Power Plants

    Mukhamad Nashir , Yanuaris Dwi Cahyono · Indonesian Geothermal Association Conference · 2013

    After separation process in a separator, two phase geothermal fluids will produce steam and brine. Power plant will produce condensate as side products. Normally, the condensate is injected through reinjection wells in order to maintain sustainability of …

    View paper: The Utilization of Brine and Condensate Waste for Small Unit Power Plants PDF: The Utilization of Brine and Condensate Waste for Small Unit Power Plants (375 KB)

  7. The CDM and Geothermal Projects, Indonesia

    Fadli Cahyono · World Geothermal Congress · 2010 ·35. Clean Development Mechanism

    Developing a geothermal power plant project is a financial challenge, and is harder than developing more traditional forms of renewable energy. One aim of the Kyoto protocol is to speed up the development of renewable energy power and indeed the evolution of …

    View paper: The CDM and Geothermal Projects, Indonesia PDF: The CDM and Geothermal Projects, Indonesia (112KB)

Papers are freely accessible. Copyright remains with the authors and conference organisers as stated on each paper.

IGA Conference Paper Database · New search