| Title | Modeling of the Fault Type Geothermal Reservoir (Dachny Site, Mutnovsky Geothermal Field) |
|---|---|
| Authors | Kiryukhin A.V., Vereina O.B. |
| Year | 2005 |
| Conference | Stanford Geothermal Workshop |
| Keywords | TOUGH2, Mutnovsky geothermal field, Dachny, fault type production zone. |
| Abstract | Fault-type geothermal fields are common in recent volcanism areas. The recent model of the Dachny site, Mutnovsky geothermal field (Kamchatka, Russia) represented as a single fault production zone with the heat exchange to ambient rocks expressed in terms of “confining beds TOUGH2 option” (Kiryukhin, Stanford Workshop 2004) was improved by add of the 5-layer external grid connected to the production zone. Sensitivity study of the external grid petrophysical properties influence on the model behavior was performed. |