Record Details

Title Production Induced Boiling and Cold Water Entry in the Cerro Prieto Geothermal Reservoir Indicated by Chemical and Physical Measurements
Authors M. A. Grant, A. H. Truesdell, A. Manon M.
Year 1981
Conference DOE-CFE Symposium on Cerro Prieto
Keywords
Abstract Chemical and physical data suggest that the relatively shallow western part of the Cerro Prieto reservoir is bounded below by low permeability rocks, and above and at the sides by an interface with cooler water. There is no continuous permeability barrier around or immediately above the reservoir. Permeability within the reservoir is dominantly intergranular. Mixture with cooler water rather than boiling is the dominant cooling process in the natural state, and production causes displacement of hot water by cooler water, not by vapor. Local boiling occurs near most wells in response to pressure decreases, but no general vapor zone has formed.

Datos quimicos y flsicos sugieren que la parte occidental relativamente somera del yacimiento de Cerro Prieto esta limitada por debajo por rocas de baja pereabilidad, y por arriba y los costados por una interfaz con aguas mas frias. Alrededor o inmediatamente por encima del yacimiento no existe una barrera continua de permeabilidad. La permeabilidad dentro del yacimiento es predominantemente intergranular. En el estado natural, la mezcla con aguas mas frias, y no la ebullicion, es el proceso de enfriamiento dominante. La produccion ha causado el desplazamiento de aguas calientes por aguas frias y no por vapor. Alrededor de la mayorla de los pozos existe localmente ebullicion en respuesta a la disminucion de presion. Sin embargo, no se ha formado una zona extensa de vapor.